14
Chapter 6 Troubleshooting
This LCD Monitor was pre-adjusted using factory standard VGA timings. Due to the output timing
differences among various VGA cards in the market, users may initially experience an unstable or unclear
display whenever a new display mode or new VGA card is selected.
Attention
This LCD Monitor Supports Multiple VGA Modes.
Refer to the Standard Timing Table for a listing of modes supported by this LCD Monitor.
PROBLEM Picture is unclear and unstable
The picture is unclear and unstable, please perform the following steps :
1. Enter PC to “Shut Down Windows” status while you’re in MS-Windows environment.
2. Check the screen to see if there are any black vertical stripes. If there are, take advantage of the “Clock”
function in OSD menu and adjust (by increment or decrement numbers) until those bars disappear.
3. Move to “Phase” function in OSD menu again and adjust the monitor screen to the most clear display.
4. Click “No” on “Shut Down Windows” and back to the normal PC operating environment.
PROBLEM There is no picture on LCD Monitor
If there’s no picture on the LCD Monitor, perform the following steps:
1. Make sure the power indicator on the LCD Monitor is ON, all connections are secured, and the system is
running on the correct timing. Refer to Chapter 3 for information on timing.
2. Turn off the LCD Monitor and then turn it back on again. If there is still no picture, press the Adjustment
Control button several times.
3. If step 2 doesn’t work, connect your PC system to another external CRT. If your PC system Functions
properly with a CRT Monitor but it does not function with the LCD Monitor, the output timing of the VGA
card may be out of the LCD’s synchronous range. Please change to an alternative mode listed in the
Standard Timing Table or replace the VGA card, and then repeat steps 1 and 2.
PROBLEM There is no picture on LCD Monitor
If you have chosen an output timing that is outside of the LCD Monitor’s synchronous range (Horizontal: 30 ~
60 KHz and Vertical: 55 ~ 75 Hz), the OSD will display an “
Over Range
” message. Choose a mode that is
supported by your LCD Monitor.
PROBLEM The IR control can't control product
Make sure if batteries are installed they are not weak batteries
If you still have difficulties you can't resolve using the tips described above, unplug and plug in the AC cord to
reset your product. Otherwise, call your local representative for servicing.
Also, if the signal cable is not connected to LCD monitor at all or properly, the monitor screen will display a
message “
No Signal
”.
Содержание XP15SSA