General
VM Series Displays RS232 User Guide
020-1359-00A
Page | 17
10.3 Power State at Cold Start Set
Bytes
Bytes Description
Bits
Description
DATA[0]
0xA3 = Power State at Cold
Start- Set
Set Power State at Cold Start
DATA[1]
Power State at Cold Start
0x00 = Power Off
0x01 = Forced On
0x02 = Last Status
The value is stored and applied only when the display starts up from cold start power state the
next time:
Power Off: The monitor will automatically switch to Power Off mode (even if the last
status was on) whenever the main power turns on, or resumes after a power interruption.
Forced On: The monitor will automatically switch to Power On mode whenever the main
power turns on or resumes after a power interruption.
Last Status: The monitor will be automatically switch to the last status (either Power Off
or On) whenever the main power turns on or resumes after a power interruption.
Example: Report status of Forced On for Power State at Cold Start (Display Address 01)
Header
Monitor ID
Category
Page
Length
Data Control
Data[0]
Data[1]
Checksum
0x21
0x01
0x00
0x00
0x04
0x01
0xA4
0x01
0x80