background image

QUICK LINKS

Contents

Index

Regulatory Compliance

Product Information

Warranty

GETTING STARTED

About the Battery System

Locate Battery Housing

Identify Connector Ports

Install Battery Fuses

USING THE BATTERY

Charge Battery

Set Up Power Management

MAINTAINING THE BATTERY

Replace Battery

Troubleshooting

APPENDIXES

Battery Disposal

Specifications

15

Invitium Battery System BAT-24CM

Battery Disposal

Industrial batteries contain lead and sulfuric acid, which are both considered 
“hazardous substances.” If batteries are improperly disposed of, for example, thrown 
in the trash or illegally dumped, these substances can eventually leak out and 
contaminate the surrounding soil and groundwater supply.

It is a federal law to properly dispose of lead-acid batteries once they can no longer be 
used. Once a battery is purchased, full liability and responsibility lies on the owner to 
dispose of the battery. 

The law says that responsibility is still on the owner if the battery is disposed of 
improperly by dumping in a landfill, or shipping to a scrap dealer who does not 
handle it properly and in which environmental damage occurs. 

It is illegal to dispose of batteries in any way other than ”thermal recovery” or 
recycling of the hazardous substances in batteries according to the Environmental 
Protection Agency (EPA). 

The Department of Transportation (DOT) has strict guidelines for the shipping of 
hazardous materials, which result in large fines if they are not followed. 

Check with your local ordinances for proper disposal procedures.

Содержание BAT-24CM

Страница 1: ...y System Locate Battery Housing Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIX...

Страница 2: ...uct does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or othe...

Страница 3: ...e Battery Troubleshooting APPENDIXES Battery Disposal Specifications iii Invitium Battery System BAT 24CM Contents Product Information iv About the Invitium Battery System 1 Locate the Battery Housing...

Страница 4: ...le is frayed or damaged replace it immediately with another of the same type and rating as supplied by Planar The safety and regulatory listing and certifications are based on cables supplied by Plana...

Страница 5: ...aning guidelines The Invitium battery system continues to operate normally while being cleaned in a fashion normal for a hospital environment Use a damp mildly soapy cloth to clean the exterior chassi...

Страница 6: ...nst water ingress IPX1 Drip Proof Equipment At a nominal load of 50 watts the battery system provides up to 4 hours of system operation The charging and monitoring electronics control the charge rate...

Страница 7: ...APPENDIXES Battery Disposal Specifications 2 Invitium Battery System BAT 24CM Locate the Battery Housing The Invitium battery system ships already installed on the Invitium cart The power cord USB ca...

Страница 8: ...fications 3 Invitium Battery System BAT 24CM Identify the Connector Ports All external connections to the battery system are located on the rear of the battery enclosure The design of the enclosure mi...

Страница 9: ...sal Specifications 4 Invitium Battery System BAT 24CM Install the Battery Fuses You need the two battery fuses and a screwdriver for this installation To install a battery fuse 1 Push the fuse in unti...

Страница 10: ...rce for charging Charge time The charging controller board is capable of independently charging the batteries while powering the attached system This ensures that the charge rate of the batteries is t...

Страница 11: ...urce and 2 powering the load When the battery has been discharged for a long period of time it reaches a point at which it needs to cut off power to its load The battery system communicates to the hos...

Страница 12: ...et Up the Power Management System All communications occur through the USB serial interface These are displayed through the Windows Power Options Properties dialog box on the host computer To set up p...

Страница 13: ...slider to the point at which you want the alarm to trigger Click the Alarm Action button to do one or more of the following select the type of notification set a computer action run a specific progra...

Страница 14: ...y System BAT 24CM 4 Select the notification you want one of the two types or both Click OK Alarm action An alarm action to hibernate or shut down can be selected in the Power Options Properties menu A...

Страница 15: ...ll Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Battery Disposal Specifications 10 Invitium Battery System...

Страница 16: ...3 Unplug the power cord USB cable and output power cable 4 Remove the two battery fuses 5 Pull out the battery enclosure carefully and move it to a flat and stable work surface The unit is heavily we...

Страница 17: ...y Disposal Specifications 12 Invitium Battery System BAT 24CM To replace the battery 1 Loosen the two screws and remove the retaining bracket 2 Detach the four battery terminal cable connectors and mo...

Страница 18: ...Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Battery Disposal Specifications 13 Invitium Battery System BAT 24CM To reinstall the battery system into the...

Страница 19: ...t acting size 5 mm x 20 mm Over temperature protection is activated Contact Planar No power supplied to Invitium system Output power cord not connected properly Make sure that output power cord is con...

Страница 20: ...ding soil and groundwater supply It is a federal law to properly dispose of lead acid batteries once they can no longer be used Once a battery is purchased full liability and responsibility lies on th...

Страница 21: ...power supply battery and charger unit packaged in a sheet metal enclosure Features Universal AC input Regulated 12V DC output Fast charging Intelligent communications USB host Cooling fan Externally a...

Страница 22: ...tery Troubleshooting APPENDIXES Battery Disposal Specifications Battery requirements Battery type Sealed lead acid quantity 2 Yuasa NP12 12 or B and B EP12 12 Capacity 12 Ah each Output voltage range...

Страница 23: ...ng mode The batteries have some level of charge and the battery system is not plugged into an AC power source During running mode the attached load to the battery system is operational The batteries d...

Страница 24: ...s to maintain 14 4 V on the battery The cooling fan is on during this cycle The 12VDC regulator circuitry is powered by the power supply and the communication system reports the charge status of the b...

Страница 25: ...ging battery 5 charging controller board 17 18 cleaning guidelines v compliance 24 components identifying 3 controller board charging 17 18 customer support 22 D discharge protection 6 discharging bat...

Страница 26: ...t Planar will arrange for return and repair of the non functioning product 1 Contact Planar via the web at http www planar com support In North America call 866 PLANAR1 866 752 6271 In Europe call 358...

Страница 27: ...ion or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized by Planar c Any damage of the product due to shipment d Removal or installation of...

Страница 28: ...OPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT DAMAGES BASED UPON INCONVENIENCE LOSS OF USE OF THE PRODUCT LOSS OF TIME LOSS OF PROFITS LOSS OF BUSINESS OPPORTUNITY LOSS OF GOODWILL INTERFERENCE WITH BUS...

Страница 29: ...ference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interference by using one or more of the following mea...

Страница 30: ...ted medical device safety standards and for the European market EC marked displays based on compliance with counsel directive 93 42 EEC commonly referred to as the Medical Device Directive MDD The fol...

Страница 31: ...ive which establishes compliance to the basic medical safety standards However EMC compliance can only be accomplished in the configured medical device or system and is the responsibility of the devic...

Страница 32: ...ct to electric shock fire mechanical and other specified hazards only in accordance with US 2601 1 and CAN CSA C22 2 No 601 1 and IEC 60601 1 for medical equipment If this mark appears with the indica...

Отзывы: