Chimney
Existing flue
-
The chimney must comply with the Current Building Regulations. If in doubt, consult your
Dealer or local Building Inspector.
-
The flue must be in good condition and must provide sufficient draught (refer to technical
details p.
29
).
-
The flue must be suitable for the installation of solid fuel
burning appliances and comply with the Current Building
Regulations.
-
The flue must be clean. It should be swept to remove soot and
dislodge tar deposits.
-
The flue must be well insulated. If the flue inner wall surfaces
are cold, a good thermal draw is impossible causing
condensation problems (tar formation etc) to occur.
-
The flue must not be shared with other appliances.
-
The chimney must be at least 4.5 m (15 ft high).
-
In case of a flat roof or when the roof gradient is lower than 15°, the stack must be 1,2 m (4
feet) high at least.
-
If the chimney has any down draught tendency, due to its position in relation to nearby
obstacles, then an anti-down draught cowl must be installed on the chimney or the chimney
height must be increased.
-
If the decompression in the chimney is excessive, a draught stabiliser must
be installed.
Chimney to be built – New flue
-
The chimney must comply with the Current Building Regulations. If in doubt, consult your
Dealer or local Building Inspector.
-
The appliance must not support the weight of the flue.
-
Consult a chimney specialist for advice on suitable flue systems for solid fuel appliances.
-
It must be distant from any combustible material (walls, cross members)
-
It must permit an easy sweeping
.
33/71
Eco Minimal 35
Содержание Eco Minimal 35
Страница 2: ...Eco Minimal 35 2 71...
Страница 15: ...15 71 Eco Minimal 35...
Страница 28: ...28 71 Eco Minimal 35...
Страница 41: ...41 71 Eco Minimal 35...
Страница 54: ...54 71 Eco Minimal 35...
Страница 67: ...Zajedni ki dio Partie Commune Common Part Gemeinsamer Teil Parte Comune 67 71 Eco Minimal 35...
Страница 68: ...6NORS JRUQMH SOR H Dessus Top Oberseite Parte Superiore 68 71 Eco Minimal 35...
Страница 69: ...6NORS ER QLFH C t Side Seite Sinistro 69 71 Eco Minimal 35...
Страница 70: ...PrednjLFa i vrata Face Avant Front Door Vorderseite T r Parte anteriore e sportello 70 71 Eco Minimal 35...
Страница 71: ...Eco Minimal 35 71 71...
Страница 72: ...Plamen d o o Njema ka ulica 36 P P 209 34000 Po ega Croatia Eco Minimal 35...