20
Stove operation in transitional periods
During the transitional periods (when external temperature exceeds 15° C), problems may be
encountered due to insufficient underpressure (poor or no draught). In such a case try to achieve necessary
underpressure level by warming up the chimney. If this does not work, do not proceed with the firing. It is
recommendable to open a window or a door of the room to equalize the internal and external air pressure.
Maintenance and cleaning
After each heating season, clean the stove, the flues and the chimney from soot deposits. Failure to
perform regular control and cleaning increases the risk of fire in the chimney. If your chimney gets on fire,
proceed as follows:
•
do not use water to extinguish the fire
•
close all air supplies to the stove and the chimney
•
after having extinguished the fire, call the chimney sweeper to inspect the chimney
•
call authorised service, i.e. the manufacturer to inspect the stove.
External surfaces of the stove are painted with heat resistant paint. After the paint has set completely
(i.e. after the second or third firing), all such surfaces may be cleaned with a soft wet cloth.
The paint above the firebox may fade with time. These surfaces may be repainted with a heat resistant
paint. Such paint is available in specialized stores.
The glass on the firebox door may be cleaned with ordinary window glass cleaner.
Should any problems occur during the operation (eg. smoke), contact your chimney sweeper or the
closest authorised service. Only authorised persons may perform any interventions on the stove and only
original spares shall be used.
Warranty
The Manufacturer's warranty applies provided that the stove is used in accordance with these
Installation and Operating Instructions.
Space heating capacities
The size of the heated place depends on the heating conditions and thermal insulation.
Subject to the heating conditions with individual heat sources having the rated output of 8 kW, it is
possible to heat up the following space volumes:
Occasional heating or heating at intervals should be considered as less favourable or even
unfavourable heating conditions.
Chimney selection
Chimney dimensioning should be based on the following data:
under favourable conditions
160 m
under less favourable conditions
105 m
under unfavourable conditions
75 m
3
3
3
Rated heating output
Flue gas flow rate
Mean flue gas temperature
Chimney negative pressure at nominal heat output
Chimney negative pressure at 0,8 nominal heat output
8
8
,9
0,12
0,10
kW
g/s
366
°C
mbar
mbar
Содержание AMITY 3
Страница 2: ......
Страница 35: ...3 x B x 59 7x76 4x51 9 cm 122 kg 8 kW EN 13240 1 120 mm 52 cm 162 2 35 2...
Страница 36: ...40 cm 60 cm 40 cm 120 cm 178 20 36...
Страница 37: ...33 cm 2 3 cc 2 5 5 kg 2 cc 2 4 kg 2 3 4 5 1 2 37 8 kW C 3 C 4...
Страница 38: ...15 8 kW 160 m3 105 m3 75 m3 38 0 8 8 8 9 0 12 0 10 kW g s 366 C mbar mbar...