To avoid risk of fire or electric shock, please do not expose this apparatus to rain or moisture. For safe 

and reliable operation, the dust covers behind the front panel should be cleaned regularly. If the 
dust filters are not maintained there will be safety risks. For example the unit can ignite the dust 
and  fire  will  occur  due  to  high  internal  temperatures.  There  is  also  risk  that  the  unit  will 
malfunction since it is dependent on constant airflow not clean and the unit malfunctions, any 

resultant problems will not be covered by the warranty.

 

1

 

Introduction 

Thank  you  for  choosing  our  power  amplifiers.  We  are  confident  that  you  will  be  pleased  with  the 

performance, configuration flexibility and reliability.

 

This  manual  provides  a  comprehensive  guide  to  the  features  and  functionality  of  D-Serie  Amps  power 

amplifiers. Please read through it to become fully acquainted with the many configuration options and multiple 
layers of protection circuitry.

 

 

Main Features 

D - Serie amplifiers incorporate a number of sophisticated technologies (many of them to ensure the 

best  possible  operaion  ).  Familiarizing  yourself  with  these  technologies  will  prove  invaluable  in 

setting up and optimizing your loudspeaker system.

 

Voltage Peak Limiter (VPL) 

The Voltage Peak Limiter (VPL) feature allows user adjustments that determine maximum voltage output, thus 

matching the amplifier to the connected speaker load.

 

Protection and performance optimization 

Appropriate  and  reliable  power  amplification  is  vital  to  any  audio  system.  Inadequate  or  faulty  power 

amplification could cause damage to the Loudspeakers, or in some cases to the power amplifiers themselves. 
To prevent any damage or costly service interruptions, D - Serie amplifiers offer advanced features to protect 
both internal circuits and any connected loads. These features even protect mains fuse that, in extreme cases, 
could be overloaded.

 

Following are short descriptions of standard built-in  protection features:

 

▲ 

CPL

(Current  Peak  Limiter)ensures  that  the  amplifier's  output  does  not  exceed  the  safe  current 

handling parameters of amplifier components.

 

▲ 

Temperature

 protection ensures that the amplifier will not be damaged by exceeding thermal limits.

 

VHF

(Very  High  Frequency)  protection  circuits  mute  the  output  of  the  amplifier  when  nondynamic 

continuous signals above 10 kHz are detected.

 

DC  protection 

ensures  destructive  DC  signals  will  not  appear  at  the  amplifier  outputs.  If  such 

 

conditions occur an internal fuse opens and fault indication is displayed.

 

Low-impedance 

(short circuit) protection provides a fault warning indication and shuts down the 

output stage when, for example, an input signal is present and a malfunctioning cable or driver is short 
circuiting the output.

 

High-impedance 

warning reports an alert when, at the same time, output signal is high and no 

current draw is measured. This situation might occur when no speakers are connected, or when a 
driver is blown.

 

Содержание D10K4

Страница 1: ...power capabilities Although the amplifier s attenuators can be used to reduce the overall gain an increase of the input signal can result in full output power which may cause damage to connected spea...

Страница 2: ...ier to the connected speaker load Protection and performance optimization Appropriate and reliable power amplification is vital to any audio system Inadequate or faulty power amplification could cause...

Страница 3: ...ier uses a forced air cooling system with air flow from front to rear maintaining a low operating temperature within defined limits Front to rear airflow is preferred as cooler air is present at the f...

Страница 4: ...anel power switch The amplifier then goes through a soft start sequence as it self checks its circuits The fans will blow at high speed before dropping to idle and the power LED will illuminate 6 Ther...

Страница 5: ...s 40dB sig to 4 dB Front Panel LED Field HI IMP High impedance open load detected TEM Temperature mute Yellow constant VHF Very High Frequency protection active output mute Red constant CPL Current Pe...

Страница 6: ...Rear Panel Overview Rear Panel for 4 Channel Amplifier...

Страница 7: ...Voltage Peak Limiter VPL Settings...

Страница 8: ...Input an d Output Connections 4 Channel...

Страница 9: ......

Страница 10: ...Input and Output Connections 2 Channel...

Страница 11: ...Bridge Mode...

Страница 12: ...r 2 Stereo Power 8 Bridged Power 4 Bridged Power Frequency Response Input Impedance 20K Balanced 10K Unbalanced THD N Rated power 4 1KHz S N Ratio Damping Factor Protection Short Circuit DC Voltage Th...

Страница 13: ...Packing Dimensions HWD mm Net Weight kgs Gross Weight kgs Specifications subject to change without notice...

Отзывы: