Models:
Measuring range:
0,1–0,8 l/min ... 35–110 l/min
liquids with viscosity up to
600 cSt,
measuring range 01/03/06 up to 200 cSt
Materials:
brass or stainless steel
Technical Data:
Max. pressure:
brass version:
300 bar (DS08.M.)
250 bar (DS08.S.)
stainless steel version:
350 bar (DS08.M.)
300 bar (DS08.S.)
Pressure drop:
0,02 bar–0,2 bar (DS08.M)
0,02 bar – 0,4 bar (DS08.S.)
Viscosity range:
30 cSt to 600 cSt
Max. media-
temperature:
100 °C (optional 160 °C)
Ex-devices under. ATEX- identification
Operating temp.:
70 °C with analogue transmitter AZ06
Electr. connection:
angle plug acc. to DIN 43650,
Ex-contact with 2 m cable
optional:
1 m cast cable
round plug M12 x 1 acc. to EN 50044,
angle plug with LED or glow lamp
Accuracy:
± 10 % of full scale
Materials:
Brass version:
Wetted parts:
measuring tube: brass (nickel plated outside)
spring:
stainless steel 1.4571
seals*:
FKM (optional NBR, EPDM)
magnet:
hard ferrite
all other wetted parts: brass
Stainless steel version (1.4571):
Wetted parts:
seals*:
FKM (optional NBR, EPDM)
magnet:
hard ferrite
all other wetted parts: stainless steel 1.4571
*only with reduced connection
Order Code:
Order number: DS08.
Variable area flow meter
and switch
S. 4. 1. 1. 06. 1. 1. 1. 0
Models:
M = miniature
S = standard
Connection:
1R = reduction to G ¼
only for measuring range 01-03
and 06-08
2R = reduction to G ½,
only for measuring range 06-12A
2
= female thread G 1/2
(Standard for DS08.M)
3R = reduction G ¾
only for measuring range 06-15A
4
= female thread G 1
(standard for DS08.S)
Materials:
1 = brass
2 = stainless steel 1.4571
Scale:
1 = for viscous medium
Measuring ranges:
Extended
measuring
ranges.:
only DS08.M:
01 = 0,1–0,8 l/min (max. 200 cSt)
03 = 0,5–1,6 l/min (max. 200 cSt)
04 = 0,8–3 l/min
05 = 2–7 l/min
only DS08.S:
06 = 0,1–0,8 l/min (max. 200 cSt)
07 = 0,5–1,5 l/min
08 = 1–4 l/min
09 = 2–8 l/min
10 = 3–10 l/min
11 = 5–15 l/min
12 = 8–24 l/min
12A = 1–20 l/min
13 = 10–30 l/min
13A = 4–40 l/min
14 = 15–45 l/min
14A = 5–50 l/min
15 = 20–60 l/min
15A = 8–60 l/min
16 = 30–90 l/min
16A = 12–70 l/min
17 = 35–110 l/min
17A = 15–80 l/min
Flow indicator:
0 =
switch only, without flow indicator
1 =
flow meter and -switch, with flow indicator
Number of contacts:
0 = without contact (only for devices with display and/or AZ06)
1 = 1 contact
2 = 2 contacts
Contact function / analogue output:
(contact or analogue transmitter available)
0 = without
1 = N/O
2 = SPDT
2X = SPDT for SPS application
3ST5 = Ex-N/O, T5 (100 °C), with 2 m cable, for DS08.S
3ST6 = Ex-N/O, T6 (80 °C), with 2 m cable, for DS08.S
3UT5 = Ex-SPDT, T5 (100 °C), with 2 m cable, for DS08.S
3UT6 = Ex-SPDT, T6 (80 °C), with 2 m cable, for DS08.S
3SM = Ex-N/O for DS08.M
3UM = Ex-SPDT for DS08.M
AZ06.1.I = analogue transmitter 4...20 mA
AZ06.1.V = analogue transmitter 0...10 V
Options:
0
= without
1
= please specify in plain text
HT = high temperature version 160 °C
M12 = round plug M12x1 acc. to EN 50044 (Tmax. 85 °C)
Kx = cable version 1 m, 2 m , 5 m, or 10 m
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S
+49 (0) 6122-7055-0 •
T
+49 (0) 6122 7055-50
[email protected] • www.pkp.de
Fl
ow