18
The corresponding fuse is switched off.
The voltage is too low.
Check the fuse.
Compare the data on the type plate with
the specifications
from your power company.
LIGHT IS ON BUT MOTOR DOES NOT WORK.
DER MOTOR RIECHT VERDÄCHTIG.
motor defective
replace motor
ÖLSPUREN.
one-way valve is leaky
connection base chimney-telescopic
chimney is leaky
seal the valve
seal the connection with a suitable
material
GERÄT VIBRIERT.
ventilation damper blocked.
motor mounting defective.
remove blockage.
replace motor.
motor not properly fixed
hood not properly fixed
fix motor properly
fix hood properly
UNGENÜGENDE ABZUGSLEISTUNG.
too much distance hood-hob
too much draught because of open
doors and/or windows
lower position of hood
close the doors/windows
GERÄT IST INSTABIL.
mounting rail is not firmly fixed
screws are not firmly tightened
fix mounting rail properly
tighten the screws