Electrical connection
Instructions for the installer (qualified professional)
The cooker is manufactured to work with three-phase alternating current
(400V3N~50Hz). Remember that the connection wire should match the
connection type and the power rating of the cooker. The connection cable must be
secured in a strain-relief clamp. The ground wire must be connected to the marked
clamp of the terminal. The electric supply of the appliance must be equipped with
an emergency switch with a distance between the contacts of at least 3 mm which
disconnects the entire appliance from the mains in a case of emergency. Read the
information on the rating label and the connection diagram before connecting the
appliance to the mains.
Move a screwdriver (1) slightly downwards (2) to open the box.
Connection diagram
Voltage heating elements 230V.
Any kind of connection: the safety
wire must be connected to the PE
terminal.
Recommended
type of
connection lead.
1 For 230 V earthed one-phase
connection, bridges connect 1-2-
3 terminals and 4-5 terminals
Protective ground to
H05VV-F3G4
2 For 400/230V earthed two-
phase connection, bridges
connect 2-3 terminals and 4-5
terminals
Protective ground to
H05VV-F4G2,5