53
6. Network Bridge Function
6.2 Communication setup
6.3 Communication port
1) In the COMMUNICATION TYPE menu, select NETWORK BRIDGE
(WIRELESS or WIRED depending on the type of connection you use) for the
CONTROL
port.
2) Using the SERIAL SETTINGS menu, select the proper baud rate and parity
for the
CONTROL
port, according to the specification of the RS-232C port of
the connected device.
For the NETWORK BRIDGE function, send the data from the computer to the
projector with using the
Network Bridge Port
that is configured in the
Port
Settings
of web browser. (
23
)
3) Using the TRANSMISSION METHOD menu, set up the proper method for the
CONTROL
port according to your use.
• The OFF is selected for the COMMUNICATION TYPE as the default
setting.
• Using the COMMUNICATION menu, set up the communication. Remember
that an unsuitable setup could cause malfunction of communication.
• When either one of the NETWORK BRIDGE settings is selected in the
COMMUNICATION TYPE menu, RS-232C commands cannot be received from
the
CONTROL
port.
• Except for 41794, 9715, 9716, 9719, 9720, 5900, 5500, 4352
between 1024 and 65535 can be set up as the
Network Bridge Port
number.
It is set to 9717 as the default setting.
NOTE
NOTE
Item
Condition
BAUD RATE
4800bps/9600bps/19200bps/38400bps
PARITY
NONE/ODD/EVEN
Data length
8 bit (fixed)
Start bit
1 bit (fixed)
Stop bit
1 bit (fixed)
To configure the setup of the communication using NETWORK BRIDGE for
the projector, use items in the COMMUNICATION menu. Open the menu of
the projector and select the OPTION - SERVICE - COMMUNICATION menu.
(
OPTION menu
>
SERVICE
>
COMMUNICATION
in the
Operating Guide
)