pizzato CS ME-20 Series Скачать руководство пользователя страница 4

Pizzato Elettrica Srl
via Torino, 1
36063 MAROSTICA (VI)
ITALY

e-mail: [email protected]
web site:  www.pizzato.com

Phone:   +39.0424.470.930

ZE FOG41A19-EU

4/12

 1 INFORMATION ON THIS DOCUMENT

1.1 Function

The present operating instructions provide information on installation, connection and 
safe use for the following articles: 

CS ME-20••••

.

1.2 Target audience

The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety 
devices are to be installed.

1.3 Application field

These instructions apply exclusively to the products listed in paragraph Function, and 
their accessories.

1.4 Original instructions

The Italian language version is the original set of instructions for the device. Versions 
provided in other languages are translations of the original instructions.

 2 SYMBOLS USED

 This symbol indicates any relevant additional information

 Attention: Any failure to observe this warning note can cause damage or mal-

function, including possible loss of the safety function.

 3 DESCRIPTION

3.1 Device description

The safety device described in this manual is defined according to the Machinery 
Directive 2006/42/EC as logic component for safety functions.
The contact expansion modules to which these usage instructions apply are devices 
specifically designed and manufactured for use on industrial machines. Upon opening 

of at least one channel, the safety function ensures that the safety relay must open its 
output contacts within the defined release time.

3.2 Device functions

 This device is suitable for the following applications: as contact expansion mod-

ule in safety circuits up to category 4 acc. to EN ISO 13849-1, up to SIL 3 acc. to 
EN 62061 and up to PL e acc. to EN ISO 13849-1 (the respective achievable category, 
SIL and PL are dependent on the upstream safety module).
- Possibility for 1- or 2-channel control.
- Connection of input channels of opposite potentials.
- Output contacts: 4 NO safety contacts, 2 NC auxiliary contacts, 1 NC feedback 
contact.
- Versions with 4 different permanently set delay times: 0.5 - 1 - 2 - 3 s.
- LED indicators for switching state of the channels 1 and 2.
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.

3.3 Intended use of the device

- The device described in these operating instructions is designed to be applied on 
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be 
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating 
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be 
considered unintended by the manufacturer. 
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications 
to it;
b) using the product in a field of application other than as described in paragraph 
TEChNICAL DATA.

 4 OPERATION

4.1 Operating diagram

CS ME20

••••-TF•

A1/A2

Y1/Y2
17/18, 27/28, 
37/38, 47/48

t

A

t

R

55/56, 65/66

Legend:

t

A

:

 Response time

t

R

:

 Release time in absence of power supply (see paragraph TEChNICAL DATA)

4.2 Wiring diagrams

1-channel control

13

14

A2

Y1

Y2

A1

F

L / +

N / -

2-channel control

13

14

A2

Y1

Y2

A1

23

24

F

L / +

N / -

 5 INTERNAL WIRING DIAGRAM

K1

K2

A1

17

27

65

A2

18

28

66

37

47

38

48

55

56

C2

C1

LED
CH1

LED
CH2

Y1

Y2

L / +

N / -

 : 

Insulated against U

imp

 6 FAULTS

LED state

Possible fault

Recommended action

CH1

CH2

- No power supply to the 

module.

- Wrong wiring.
- Power supply conductor/s cut.
- External fuse broken.
- Short circuit between chan-

nels.

- Failure in base module.
- Internal expansion module 

fault.

Check the wiring, the fuse and 
the function of the base module.
If the fault persists, replace the 
module.

CS ME-20  

expansion module

Manual start

Automatic start

Start input,  
reset and/or feedback

Base module

CS ME-20  

expansion module

Manual start

Automatic start

Start input, reset 
and/or feedback

Base module

Содержание CS ME-20 Series

Страница 1: ...anali Collegamento dei canali d ingresso a potenziali opposti Contatti d uscita 4 contatti NO di sicurezza 2 contatti NC di segnalazione 1 contatto NC di retroazione Versioni con 4 differenti tempi fi...

Страница 2: ...mente anche se ancora funzionante La data di produzione posta vicino al codice prodotto vedi paragrafo MARCATURE 7 4 Cablaggio Attenzione Non eseguire l installazione del modulo di sicurezza in presen...

Страница 3: ...MALTIMENTO Il prodotto deve essere smaltito correttamente a fine vita in base alle regole vigenti nel paese in cui lo smaltimento avviene 12 SUPPORTO Il dispositivo pu essere utilizzato per la salvagu...

Страница 4: ...ety module Possibility for 1 or 2 channel control Connection of input channels of opposite potentials Output contacts 4 NO safety contacts 2 NC auxiliary contacts 1 NC feedback contact Versions with 4...

Страница 5: ...Power the device only when the electrical circuits have been completely realized according to the speci fications indicated in the OPERATION paragraph The first time you start the machine ensure that...

Страница 6: ...our technical support service Pizzato Elettrica Srl Via Torino 1 36063 Marostica VI ITALY Telephone 39 0424 470 930 E mail tech pizzato com www pizzato com Our support service provides assistance in I...

Страница 7: ...anaux Raccordement des canaux d entr e potentiels oppos s Contacts de sortie 4 contacts NO de s curit 2 contacts NC de signalisation 1 contact NC de r troaction Versions avec 4 temps de retard fixes d...

Страница 8: ...emplacer le dispositif m me s il marche encore La date de fabrica tion est indiqu e c t du code du produit voir paragraphe MARQUAGES 7 4 C blage Attention Ne pas installer le module de s curit en pr s...

Страница 9: ...t tre limin de mani re appropri e la fin de sa dur e de vie selon les r gles en vigueur dans le pays o il est d mantel 12 SUPPORT Le dispositif peut tre utilis pour garantir la s curit physique des pe...

Страница 10: ...erung Anschluss von Eingangskan len mit entgegengesetzten Potenzialen Ausgangskontakte 4 NO Sicherheits Kontakte 2 NC Meldekontakte 1 NC R ckf hrkontakt Ausf hrungen mit 4 verschiedenen fest eingestel...

Страница 11: ...rt Das Fertigungsdatum befindet sich neben der Artikelnummer vgl Abschnitt BESCHRIFTUNGEN 7 4 Verdrahtung Achtung Bei anliegender Versorgungsspannung darf die Installation des Si cherheits Moduls nich...

Страница 12: ...rhalten hat 11 ENTSORGUNG Nach Ablauf der Gebrauchsdauer muss das Ger t nach den Vorschriften des Landes entsorgt werden in dem die Entsorgung stattfindet 12 KUNDENDIENST Das Ger t kann f r den Person...

Отзывы: