5. 2 RS-485 Communication Mode Selection
DIP SWITCH
3
2 wiring system (HALF duplex)
OFF
4 wiring system (FULL duplex)
ON
Communication Mode of HALF: Most of systems use this mode because of low-cost and easy
setup, but this mode can’t receive and transmit data simultaneously.
Communication Mode of FULL: This Mode can receive and transmit data simultaneously.
5.3 Transmission Speed Setting
BAUD RATE SELECTION
DIP SWITCH
4
5
2400 bps
ON
ON
4800bps
OFF
ON
9600 bps
ON
OFF
19200 bps
OFF
OFF
Remark: LILIN Protocol use Baud Rate 9600bps.
5.4 Protocol Setting
PROTOCOL SELECTION
DIP SWITCH
6
7
8
9
MLP 1 VERSION
OFF
ON
ON
ON
5. 5 RS-485 Protocol DIP Switch for P465 Setting
RS-485 PROTOCOL DIP SWITCH SETTING
DIP
SWITCH
1 2 3 4 5 6 7 8 9 10
MLP 1
VERSION
ON ON OFF ON OFF OFF ON ON ON OFF