background image

3

1-pin Connector

Fuse Power Cable

OBD Cable

Diagnostic Monitoring 
Connector

Yellow

Red

Red

① 

Remove the standard tachometer

Remove the screw from the hole at the 
back of the tachometer.

Put the bolt store in a safe place.

Line up the screw holes on the original 
tachometer with the screw holes on 
the meter holder and lightly fasten with 
the double-sided tape.

Do not press to strongly on the tape; 

it may become difficult to remove.

When installing, please make adjust-
ments to line up the meters on each 
side.

Unscrew the two screws (torque screw T30 x 2) from the base at the back of the tachom-
eter and remove it by pulling it forward. (As the wiring for the tachometer is connected to 
inside the steering column it cannot be removed. Carry out all operations with the wiring 
pulled out but connected.)

Make sure not to lose any removed parts.

Affix the supplied meter holder to the back
of the standard tachometer.

Remove

② 

Unscrew the screws at the
back of the tachometer

⑥ 

Return the tachometer
to its original position

Return the tachometer to its original 
place by going in the reverse order 
from 

 above, and securely fasten 

with the two screws.

Tachometer
(Backside)

Two screws
(torque screw

T30 x 2)

Cable

Cable

Cable

Installing without
removing tachometer

Tachometer
(Backside)

Hole

Two screws

① 

Locate the Diagnostic Monitoring

Connector Position

 

Remove the Cover of the Fuse Box

④ 

Lightly Fasten the Meter

Holder

A f f i x t h e p r ov i d e d d o u b l e - s i d e d t a p e 
(round) to the two places as shown in the 
figure to the right.

③ 

Affix Double-sided Tape to
the Stay on the Meter Holder

Use the provided tap screws to fasten.

Meter Holder (Backside)

Tachometer (Backside)

Tap screw
(included)

⑤ 

Fix the meter holder with
the screws

⑦ 

Fasten the meter to the
meter holder

Affix the provided cushion tape to two 
places on the sides of the meter. Pull 
the meter cable through the hole at the 
back of the meter holder and insert it 
into the 5-pin connector at the back of 
the meter. After having decided the 
angle press the meter into the holder 
at finish the installation.

Double-sided Tape
(round)

Diagnostic Monitoring

Connector

Diagnostic Monitoring

Connector

Diagnostic Monitoring

Connector

Diagnostic Monitoring
Connector

Diagnostic Monitoring
Connector

Diagnostic Monitoring
Connector

Open

Open

Open

Cover

Cover

Cover

② 

Open the Cover

③ 

Completely insert the OBD
Connector

 

Insert the Fuse

Fuse Box

Fuse Box

Fuse Box

Cover

Remove the fuse for IGN (12 V with key 
switch ON), and insert the 7.5 A mini-
fuse from the fuse power cable.

Use a flathead screwdriver or such tool to remove 
the cover of the fuse box found on the side of the 
panel to the right of the steering wheel.

Connecting The OBD Connector

2

Fastening The Meter

3

Connecting to a Power Source

1

I GN

Cut

Fuse

= Cut connector

(or soldering)

If you are unable to get power 
fr o m  t h e  f u s e  b ox ,  p l e a s e 
wire directly to IGN (12V with 
key in ON position). 

Insert the OBD connec-
t o r t o t h e d i a g n o s t i c 
monitoring connector 
from the Unit.

Meter Holder
(Backside)

Cushion tape (two places)

Meter Holder

Meter Holder

Meter Cable

(Front of the fuse box)

Position = 4th column from the left

and 5th row from the top

Number = 32 or 34

Capacity = 7.5A

e.g. BMW MINI COOPER SU16 (steering wheel on right, 2010 MODEL)

If you wish to get power from a fuse 

other than the 7.5A mini-fuse, please 
purchase separately.

Example of a place of specific fuse

Fuse
(included)

Fuse
(included)

Fuse
(included)

(Not as normal 

power source)

The following is just one example of wiring to the fuse box of a BMW MINI COOPER SU16 (steering wheel 
on right). If your model is different and you are unsure of how to connect please contact your dealer.

(e.g.)

Содержание 52X-NA

Страница 1: ...oduct When double sided tape is used for an installation be warned that when hot the tape temporar ily losses adhesiveness Do Not Use Chemical Cleansers If the unit gets dirty please wipe with a soft cloth to remove any dirt Do not use chemical cleansers such as thinner benzene or alcohol Do not install the product in any place subject to high temperature or any place where water may be splashed M...

Страница 2: ... needle will move to the lowest value side several times then it will move to the maximum value and finally to reading for current measurement item Unit View from Car Connection View from Meter Connection Meter connector Connect gauge cable 1 Power connector Connect OBD Cable 2 Spare No need to use 3 Check Battery 1 2 Illumination Keep lighting the meter in operation Needle Red Dial Orange OBD MET...

Страница 3: ... the meter to the meter holder Affix the provided cushion tape to two places on the sides of the meter Pull the meter cable through the hole at the back of the meter holder and insert it into the 5 pin connector at the back of the meter After having decided the angle press the meter into the holder at finish the installation Double sided Tape round Diagnostic Monitoring Connector Diagnostic Monito...

Страница 4: ...e Clean to remove oil and dust How to use the Cut Connectors Peel off of the vinyl cover at connection Peel off of the vinyl cover at the end of the product s wire Wrap around both wire coils Close tightly with cut connector Insulate with vinyl tape Real time display Meter OFF Key Switch OFF Engine stop Key Switch ON Engine start Opening Demo Start up all together Trouble Possible Causes Possible ...

Отзывы: