background image

1

52X-NA  As of May, 2015  No.1)

Features

Cushion

Tape

× 2

Meter Holder

×2

User’ s 
Manual

Double-sided

Tape

(Square) 

Double-sided

Tape

(Round) × 4 

Tap Screw

×2

Double Gauge Set for MINI

52X-NA

USER’ S MANUAL

Product

If this pro du c t is g iven to 

another user, make sure to 
include this User’ s Manual.

Thank you for purchasing this PIVOT product.

Please read this manual carefully and keep it for future refer-

ence.

Contents

Contents / WARNING / CAUTION

……

1

Features

…………………………………

1

Part Names and Displays

………………

2

Connecting The Wires and

Installing The Product 

……………

2

~

4

Basic Operation

…………………………

4

Troubleshooting

…………………………

4

Voltage

Meter

Water Temp

Meter

Zip Ties

(Large) × 2
(Small) × 5

Gauge Cable

×3

Please check the contents of the package

Fuse Power Cable

with fuse 3A

Unit

OBD Cable

with fuse 3A

Cut 

Connector

Do not work in areas where there is excessive exhaust.

    Due to vehicle exhaust emission poisoning or fire may result in a 

damage to humans.

Do not crush the cable.

    Please be careful that the cable does not get crushed by the seat rail or 

car door steel plate, nor cut by any sharp steel plate as this may cause 
a poor connection or an electric short leading to fire or other danger.

Do not operate while driving.

    O perating or checking the display during driving may cause an 

accident; please use with the utmost consideration for safety.

Please securely fasten the product to a stable place and 
be sure to store bundle away all wires with tape, etc...

    It is very dangerous to pull tangled wires by force or allow tangled wires 

to interfere with driving.

This product is for DC12V cars;

     Installation cannot be carried out on cars with other voltage batteries.

Just after installation do not exert any strong force on the product.

    When double-sided tape is used for an installation be warned that when hot the tape temporar-

ily losses adhesiveness.

Do Not Use Chemical Cleansers.

    If the unit gets dirty please wipe with a soft cloth to remove any dirt. Do not use chemical 

cleansers such as thinner, benzene, or alcohol.

Do not install the product in any place subject to high temperature or any 

place where water may be splashed.

Make sure to replace all screws and parts to their original place.

Do not install the product in a place where it will cause distraction.

Do not, in any manner, process, take apart, or make changes to this product.

WARNING

Improper use or disregard of these 
warnings may result in the injur y or 
death of people.

CAUTION

Improper use or disregard of these warnings may cause injury 
to persons, damage the product and other things.

Simple Connector Installation 

Install by simply connecting to the diagnostic monitor connector and fuse box.

Specialized Meter Holder 

Lightweight meter holder with superior adhesion means less movement under vibration.  

LED Illumination 

Uses same orange Illumination as that of standard meters.

1. The display will not be proper if the ECU being used is not the standard one or if a sub-computer is being used, even in 

compatible car models.

2. Cannot be used in combination with other company’ s products that use Diagnostic Monitoring Connectors.
3. For details about using in combination with other PIVOT products that use Diagnostic Monitoring Connectors please see our 

Web Site at

 

 

 

htt p://p ivotj p.c om/o bd - e/

.

4. The meter holder can become extremely hot when exposed to direct sunlight; be particularly careful of burns.

Just by connecting to the diagnostic monitoring connector, the MINI specialized CAN communication can be analyzed and 
Boost and Water temperature data can be simultaneously displayed. (Not for use with incompatible models)

Содержание 52X-NA

Страница 1: ...oduct When double sided tape is used for an installation be warned that when hot the tape temporar ily losses adhesiveness Do Not Use Chemical Cleansers If the unit gets dirty please wipe with a soft cloth to remove any dirt Do not use chemical cleansers such as thinner benzene or alcohol Do not install the product in any place subject to high temperature or any place where water may be splashed M...

Страница 2: ... needle will move to the lowest value side several times then it will move to the maximum value and finally to reading for current measurement item Unit View from Car Connection View from Meter Connection Meter connector Connect gauge cable 1 Power connector Connect OBD Cable 2 Spare No need to use 3 Check Battery 1 2 Illumination Keep lighting the meter in operation Needle Red Dial Orange OBD MET...

Страница 3: ... the meter to the meter holder Affix the provided cushion tape to two places on the sides of the meter Pull the meter cable through the hole at the back of the meter holder and insert it into the 5 pin connector at the back of the meter After having decided the angle press the meter into the holder at finish the installation Double sided Tape round Diagnostic Monitoring Connector Diagnostic Monito...

Страница 4: ...e Clean to remove oil and dust How to use the Cut Connectors Peel off of the vinyl cover at connection Peel off of the vinyl cover at the end of the product s wire Wrap around both wire coils Close tightly with cut connector Insulate with vinyl tape Real time display Meter OFF Key Switch OFF Engine stop Key Switch ON Engine start Opening Demo Start up all together Trouble Possible Causes Possible ...

Отзывы: