Piusi SQUALO35 Скачать руководство пользователя страница 12

M0467A

30 

/124

Installation, use and maintenance

The tank in which the pump is being installed must be vented in accordance 

with manufacturer’s installation instructions. Follow the tank manufactur-

er’s tank installation instructions.

- Make sure that the tank is free from sand, dirt, and other debris.

- Cable extension junctions should only be made with a safe and water-

proof system.

As a general rule of electrical safety it is always recommended to power 

the device by protecting the line with:

- Magnetothermic switch / disconnector with current flow rate suitable for 

the electric line;

- 30 mA differential residual current device.

The electrical connection must have a circuit breaker (gfci).

- The pump cannot be run dry

During installation and periodically, provide for verification of the ground-

ing circuit in compliance with current regulations.

In order to prevent deformations and breakages, make sure that the pipes 

do not exert excessive forces on the delivery port of the pump.

11.1  POSITIONING, CONFIGURATIONS AND ACCESSORIES

ATTENTION

It is the responsibility of the installer to provide the necessary line acces-

sories to ensure the correct and safe operation of the pump.  The accesso-

ries that are not suitable to be used with the previously indicated material 

could damage the pump and/or cause injury to persons, as well as causing 

pollution.

ATTENTION

To maximise performance and prevent damage that could affect pump op-

eration, always demand original accessories.

11.2  NOTES ON DELIVERY LINES

EFFECTS ON 

FLOW RATE

Length and diameter of pipe, flow rate of dispensed liquid, accessories fitted, 

can create back pressures above those allowed. 

In this case, the pump mechanical control (pressure regulator) will trip to re-

duce the flow rate.

HOW TO 

REDUCE 

EFFECTS ON 

FLOW RATE

To avoid these problems, system flow resistances must be reduced using 

shorter and/or larger diameter pipes, as well as line accessories with low 

resistances (e.g., automatic nozzle for higher flow rates).

A product filter must be installed between the tank / piping and the dispens-

ing point. The filter should be sized to insure that AUS32 (DEF, AdBlue®) sup-

plied to the dispenser nozzle meets the requirements of ISO 22241 and does 

not pass particulates that may clog the injector nozzles in the vehicle.

CHARACTER-

ISTICS OF 

DELIVERY 

PIPES

The delivery pipe must have the following technical characteristics:

- recommended minimum nominal diameter: 3/4” (DN20)

Only use hose with a cylindrical male thread. Do not use conical threads 

to avoid damage to the connections.

Содержание SQUALO35

Страница 1: ...Bulletin M0467A ml_00 piusi SQUALO35 submersible pump ...

Страница 2: ...ES 25 8 TECHNICAL DATA 25 9 OPERATING CONDITIONS 26 9 1 ENVIRONMENTAL CONDITIONS 26 9 2 ELECTRICAL POWER SUPPLY 26 9 3 DUTY CYCLE 26 10 INTENDED USE 27 10 1 PERMITTED AND NON PERMITTED FLUIDS 27 10 2 USE 27 11 INSTALLATION 29 11 1 POSITIONING CONFIGURATIONS AND ACCESSORIES 30 11 2 NOTES ON DELIVERY LINES 30 12 CONNECTIONS 31 12 1 ELECTRICAL CONNECTIONS 31 13 INITIAL START UP 32 14 EVERY DAY USE 33...

Страница 3: ...ompatibility Directive 2014 30 EU The documentation is at the disposal of the competent authority following motivated request at Piusi S p A or following request sent to the e mail address doc_tec piusi com The person authorised to compile the technical file and draw up the declaration is Otto Varini as legal representative Suzzara 01 03 20 Otto Varini legal representative 2 2 DECLARATION OF COMPA...

Страница 4: ...e supported or transport ed to the power cord Be use it to the appropriate handle name code weight WEIGHT Kg PACKAGING DIMENSION mm 7 200 x 200 x 430 4 GENERAL WARNINGS Warnings To ensure operator safety and to protect the dispensing system from poten tial damage workers must be fully acquainted with this instruction manual before attempting to operate the dispensing system Symbols used in the man...

Страница 5: ...maintenance work are carried out disconnect the power source FIRE AND EXPLOSION When flammable fluids are present in the work area such as gasoline and windshield wiper fluid be aware that flam mable fumes can ignite or explode To help prevent fire and explosion Pump not suitable for pumping flammable liquids or operating in explosive environments ELECTRIC SHOCK Electrocution or death FThis pump m...

Страница 6: ...Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Donotkinkoroverbendhosesorusehosestopullequipment Keep children and animals away from work area Comply with all applicable safety regulations BURN HAZARD To avoid severe burns do not touch hot flui...

Страница 7: ... cleaning products PERSONAL PROTECTIVE EQUIPMENT THAT MUST BE WORN Safety shoes Close fitting clothing Protection gloves Safety goggles OTHER DEVICES Instructions manual 8 TECHNICAL DATA Voltage Frequency V Hz Absorp tion A Power W Hp RPM Nominal FlowRate l min Max Back Pressure bar psi Type of Service S1 continuous S3 periodic intermittent Tank minimum level mm in 230 50 60 4 0 560 0 75 2850 3600...

Страница 8: ...Consult the fluid data sheet for the range of use 9 2 ELECTRICAL POWER SUPPLY NOTE The pump must be powered by a single phase line in alternating current whose nominal values are indicated in the table in the paragraph TECHNICAL DATA The maximum acceptable variations for the electrical parameters are Voltage 5 of the nominal value ATTENTION Powersupplyfromlineswithvaluesthatdonotfallwithintheindic...

Страница 9: ...EALS WATER FLUID CONTAMINATION FOODLIQUIDS FLUID CONTAMINATION 10 2 USE INTENDED USE AND CHARACTER ISTICS The submersible pumps SQUALO35 have been designed and fabricated for AUS32 DEF AdBlue delivery systems The pump is provided with Regenerative turbine actuated by a proper electrical motor Pressure regulator A check valve to prevent the discharge pipe from being delivery Electronic board with t...

Страница 10: ...omply with the Directive 2014 34 UE ATEX 6 To add systems or equipment not planned by the manufacturer in the executive project 7 Connect the pump to sources of energy other than those prescribed by the manufacturer and reported in the instructions for use 8 To run the pump without having read and fully understood the user manual 9 To run the pump to deliver other fluids than AUS32 DEF AdBlue 10 T...

Страница 11: ...quipment required for the correct func tioning of the pump only use accessories that have been supplied with the system ATTENTION The use of accessories that are unsuitable and were not provided with the system is strictly prohibited Piusi S p A accepts no responsibility for dam age to persons property or the environment caused by failure to comply with this requirement THE PUMP IS FOR PROFESSIONA...

Страница 12: ... the pump The accesso ries that are not suitable to be used with the previously indicated material could damage the pump and or cause injury to persons as well as causing pollution ATTENTION To maximise performance and prevent damage that could affect pump op eration always demand original accessories 11 2 NOTES ON DELIVERY LINES EFFECTS ON FLOW RATE Length and diameter of pipe flow rate of dispen...

Страница 13: ...A and the installation environment SINGLE PHASE WIRING Connect the cable of the single phase pump to the electric panel ensuring that the following parts correspond SINGLE PHASE WIRING DIAGRAM GREEN YELLOW CABLE BROWN CABLE LINE BLUE CABLE NEUTRAL The pump should be installed with an electric panel guaranteeing the follow ing functions overload protection short circuit protection dry run protectio...

Страница 14: ... difficult because of the automatic stopping device that keeps the valve closed It is recommended that the automatic nozzle be temporarily removed during initial start up PRELIMINARY CHECK Before start up the suction part of the pump must be primed Prime by means of submerging the entire pump in AUS32 DEF AdBlue this ensures that the sealing surfaces are properly lubricated and that the pump can i...

Страница 15: ... breakage of the pump components TIMER OPTIONAL The pump is provided with a timer that switches it off automatically after about 6 minutes of running ATTENZIONE In case of pump automatic shut off through the timer switch off and switch on the pump through the main switch 15 MAINTENANCE Safety instructions The SQUALO35 pump has been designed and built to require minimal main tenance Before carrying...

Страница 16: ... WHEN STARTING Low voltage in the electric power line Bring the voltage back within the anticipated limits LOW OR NO FLOW RATE Low level in the suction tank Refill the tank Filter clogged Clean the filter High loss of head in the delivery circuit Use shorter piping or of greater diameter Low rotation speed Check the voltage at the pump Adjust the voltage and or use cables of greater cross section ...

Страница 17: ...within the European Union European Directive 2012 19 EU requires that all equipment marked with this symbol on the product and or packaging not be disposed of together with non differentiated urban waste The symbol indicates that this product must not be disposed of together with normal household waste It is the responsi bility of the owner to dispose of these products as well as other electric or...