background image

8 DISPOSAL

Foreword

If the system needs to be disposed, the parts which make 

it up must be delivered to companies that specialize in the 

recycling and disposal of industrial waste and, in particular:

Disposing of pack-

ing materials

The packaging consists of biodegradable cardboard which 

can be delivered to companies for normal recycling of cel-

lulose.

Metal Parts Dis-

posal

Metal parts, whether paint-finished or in stainless steel, can 

be consigned to scrap metal collectors.

Disposal of electric 

and electronic 

components

These must be disposed of by companies that specialize in 

the disposal of electronic components, in accordance with 

the indications of directive 2002/96/CE (see text of directive 

below).

   Informa-

tion regard-

ing the en-

vironment 

for clients 

residing 

within the Euro-

pean Union

European Directive 2002/96/EC requires that all equipment 

marked with this symbol on the product and/or packaging 

not be disposed of together with non-differentiated urban 

waste. The symbol indicates that this product must not be 

disposed of together with normal household waste. It is the 

responsibility of the owner to dispose of these products 

as well as other electric or electronic equipment by means 

of the specific refuse collection structures indicated by the 

government or the local governing authorities.

Miscellaneous 

parts disposal

Other components, such as pipes, rubber gaskets, plastic 

parts and wires, must be disposed of by companies special-

ising in the disposal of industrial waste.

Содержание PW-LAN

Страница 1: ...M0270 ITEN_00 PW LAN ...

Страница 2: ...Y RULES 24 4 3 PACKAGING 25 4 4 PACKAGECONTENTS PRE INSPECTION 26 4 5 MACHINE AND MANUFACTURER IDENTIFICATION 26 5 TECHNICAL FEATURES 27 6 OVERVIEW 28 7 INSTALLATION 28 7 1 FIXINGTOTHEWALL 29 7 2 WIRE CONNECTION 29 7 3 LED CONNECTORS 31 7 4 GETTING STARTED 32 7 5 NAVIGATION 34 7 6 NETWORKTAB 34 7 7 SYSTEMTAB 35 7 8 RS485TAB 35 7 9 PROCEDURETO RESTORE FACTORY SETTINGS 36 8 DISPOSAL 37 ...

Страница 3: ... representative Suzzara 01 01 2013 OttoVarini legal representative 3 GENERAL WARNINGS Important precautions To ensure operator safety and to protect the pump from potential damage workers must be fully acquaint ed with this instruction manual before performing any operation Symbolsused inthemanual The following symbols will be used throughout the manual to highlight safety information and precauti...

Страница 4: ...or to protect yourself while you move the injured person away from any electrical conductor Avoid touching the injured person with your bare hands until he is far away from any conductor Immediately call for help from qualified and trained personnel Do not operate switches with wet hands NOTE Please refer to the safety data sheet for the product ...

Страница 5: ...down DANGER Installation operations are carried out with the box open and accessible electrical contacts All these ope rationshavetobedonewiththeunitisolatedfromthe power supply to prevent electrical shock All work related to electrical installation must be per formed by qualified installer electrical or electronic Wear insulated gloves for electrician ATTENTION As a general rule of electrical saf...

Страница 6: ...immediately the cable connection to the network if it is damaged ATTENTION The maintenance of the electrical parts can be done only by qualified installer electrical or electronic Wear insulated gloves for electrician Before performing any maintenance make sure to unplug the device from the power supply to turn it off and isolate it from the mains If the device is sold without cable to provide per...

Страница 7: ... LAN comes with an identification plate this is attached externally and contains the following in formation model lot number Production year technical data ATTENTION Before installing always make sure the type of dispensing system is correct and suitable for the available power supply Voltage Frequency Make sure that the plate does not deteriorate or be come detached over time NOTE Should this sit...

Страница 8: ...270 EN 27 EN 5 TECHNICAL FEATURES Dimensions Length A 180 mm Depth B 60 mm Height C 160 mm Weight 330 g TechnicalSpecifications Voltage 100 230 Vac Frequency 50 Hz 60 Hz Max power 15W Protectiongrade IP54 ...

Страница 9: ... BOX OCIO MCO SYSTEMREQUIREMENTS OPERATING SYSTEM MicrosoftWindows XP WindowsVista Windows 7 Windows 8 WEB BROWSER Mozilla Firefox Apple Safari Google Chrome Microsoft Internet Explorer 8 or above 7 INSTALLATION ATTENTION The installation operations are performed with door open and power contacts accessible All these operations must be performed with the appliance isolated from the power mains to ...

Страница 10: ... M4 screws 80 35 25 156 13 5 10 Ø 4 5 7 2 WIRE CONNECTION FOREWORD Removing the frontal case it is possible to make all the necessary wiring To do a proper operation perform the following steps 1 Fix the the RS485 twisted cable as shown below 2 Fix the three power supply cable as shown below Input 100 240Vac 50 60 Hz ...

Страница 11: ...ble category5orhigher Themax distance thatcanbereachedis90metres Themaximumdistanceis alsoaffectedbytheexistingnetworkarchitecture WIREDPW LAN RS485 POWER ETHERNET ATTENTION Fix the power cord with the clip provided so that any separation of the cable from the terminals does not lead to dangerous vol tages other cables connected to the outside ...

Страница 12: ...r 100 240Vac 50 60 Hz connector LED FLASHING EQUIVALENCE D1 OFF No traffic from RS485 SLOW FLASH Traffic from RS485 D2 OFF DCHP Disabled Customized IP different from 192 168 2 10 ON DHCP Enabled SLOW FLASH DCHP Enabled NoIPfrom DHCPserver FallbackIP 192 168 2 10 FAST FLASH DHCP Disabled Standard IP 192 168 2 10 D4 ON LAN signal D5 ON Power ON ...

Страница 13: ... the Ethernet adapter on your computer with a static IP address on the 192 168 2 x subnet for example IP address 192 168 2 150 and subnet mask 255 255 255 0 3 Configure internet options of your browserWITHOUT proxy server 4 Launch yourWeb browser Enter the default IP address of your device in the address field Press Enter PC or Return Mac Device DefaultIPAddress PW LAN 192 168 2 10 5 Enter admin i...

Страница 14: ...M0270 EN 33 EN ...

Страница 15: ...wstoconfigureTCP IPv4parameters 1 CaseDHCPClient 2 CaseStaticIP ITEM SETTING DEVICENAME Specifiesthehostname MANAGEMENTIP ADDRESS YouchoosestheformalityofmanagementoftheIPofthedeviceamong2options DHCPClientthatitmeansthatinthelannetworkexistaDHCPserverthatassignsadynamic IPtothePW LAN anaddressIPoftheGatewayandanaddressDNStothedevice StaticthatmeansthattheadministratorofnetassignsafixedstaticIPtot...

Страница 16: ...ytheIPaddressoftheprimaryDNS DomainNameSystem server SECONDARY DNSIP SpecifytheIPaddressofthesecondaryDNSserver Thisentryisoptionalandusedonlyiftheprimary DNSserverisnotresponding 7 7 SYSTEM TAB FOREWORD The SystemTab controlstheadministratoraccountmanagement NEW PASSWORD Enterthenewpasswordfortheadministratoraccount VERIFYNEWPASSWORD Re enterthenewpasswordfortheadministratoraccount 7 8 RS485 TAB ...

Страница 17: ...taff experi encedonthedangersoftheelectricalpower Thestaffmustwearinsulatingglovesinorder to The procedure is as fo lplorwevse 1 Remove supply voltage to the device 2 Open the box with the 4 screws 3 Locate the RESET button as shown in the previous paragraphsi 4 Press and hold the RESET button while you power ATTENTION Thisprocedureisverydangerousbecauseyouarenearpoints withdangerousvoltageonthebo...

Страница 18: ...ications of directive 2002 96 CE see text of directive below Informa tionregard ingtheen vironment forclients residing withintheEuro peanUnion European Directive 2002 96 EC requires that all equipment marked with this symbol on the product and or packaging not be disposed of together with non differentiated urban waste The symbol indicates that this product must not be disposed of together with no...

Страница 19: ......

Страница 20: ......

Страница 21: ...Piusi S p A Suzzara Mantova Italy M0270 ITEN_00 ...

Отзывы: