Piusi E120 Скачать руководство пользователя страница 1

Bulletin M0064C IT/EN - Rev.1

Copyright

!   WARNING

In  the  case  that  the  suction  tank  is  higher  than  the  pump,  it  is  advisable  to  install 
an antisiphon components.

ENGLISH 

(Translated from Italian)

ENGLISH 

(Translated from Italian)

ENGLISH 

(Translated from Italian)

ENGLISH 

(Translated from Italian)

ENGLISH 

(Translated from Italian)

INDEX

A

E.2  ELECTRICAL SPECIFICATIONS

E.1  PERFORMANCE SPECIFICATIONS

MACHINE AND MANUFACTURER IDENTIFCATION

B

DECLARATION OF INCORPORATION OF PARTLY-COMPLETED MACHINERY 

C

MACHINE DESCRIPTION

D

MOVING AND TRANSPORT

G

INSTALLATION

H

TECHNICAL SPECIFICATIONS

E

Available Models:

MANUFACTURER:

IDENTIFICATION PLATE 

(EXAMPLE WITH THE FIELDS IDENTIFIED): 

• E80     • E120

PIUSI SPA 
VIA PACINOTTI Z.I. RANGAVINO
46029 SUZZARA (MN) 

Self-Priming,  volumetric,  rotating  electric  vane  pump,  equipped  with  by-pass 
valve.

Asynchronous motor, single-phase and three-phase, 4 pole, closed type (protection 
class IP55 in conformance with EN 60034-5-86 regulations) self-ventilated, directly 
flanged to the pump body.

Given the limited weight and size of the pumps (see overall dimensions), 

moving the pumps 

does not require the use of lifting devices

.

The pumps were carefully packed before shipment.
Check the packing material on delivery and store in a dry place.

The performance diagram shows flow rate as a function of back pressure.

PUMP:

MOTOR:

The pumps are furnished without line accessories. Following is a list of the most common line 
accessories whose use is compatible with the proper functioning of the pumps.

Single-phase motors

 are supplied with a pre-existing 2-meter cable with electric plug.

To  change  the  cable,  open  the  terminal  strip  cover  and  connect  the  line  according  to  the 
following diagram:

Single-phase motors are supplied with a bipolar switch and capacitor wired and installed
inside the terminal strip box (see diagram).

The characteristics of the capacitor are shown on the identification plate for each pump model.

The switch has the sole function of starting/stopping the pump and cannot in any way substitute 
for the main circuit breaker provided for in the applicable regulations.

Index
Machine and manufacturer identification 
Declaration of incorporation 

Machine description
Technical specifications

E.1

 Performance specifications

E.2

 Electrical specifications

Operating conditions

F.1

 Environmental conditions

F.2

 Electrical power supply

F.3

 Working cycle

F.4

 Fluids permitted / Fluids not permitted

Moving and transport
Installation

of 

partly-completed Machinery

H.1

 Disposal

H.2

 Preliminary inspection

H.3

 Positioning the pump

H.4

 Connecting the tubing

H.5

 Considerations regarding   

       delivery and suction lines

H.6

 Line accessories

H.7

 Electrical connections

Initial start-up
Daily Use
Problems and solutions
Maintenance
Noise level
Exploded diagrams
Dimensions and weights

A
B
C

D
E

F

G
H

I
L
M
N
O
P
Q

H.6  LINE ACCESSORIES

OPERATING CONDITIONS

F

F.4  FLUIDS PERMITTED / FLUIDS NOT PERMITTED

 • DIESEL FUEL at a viscosity of from 2 to 5.35 cSt (at a temperature of 37.8°C)
    Minimum flash point (PM): 55°C

PERMITTED:

NOT PERMITTED:

RELATED DANGERS:

• GASOLINE
• INFLAMMABLE LIQUIDS WITH PM < 55°C
• LIQUIDS WITH VISCOSITY > 20 cSt
• WATER
• FOOD LIQUIDS
• CORROSIVE CHEMICAL PRODUCTS

• SOLVENTS

DELIVERY:

SUCTION:

• Automatic dispensing nozzle
• Manual dispensing nozzle
• Meter
• Flexible tubing

• Foot valve with filter
• Rigid and flexible tubing
• Pump suction filter

H.4  CONNECTING THE TUBING

H.5  CONSIDERATIONS REGARDING DELIVERY AND SUCTION LINES

DELIVERY

The choice of pump model must be made keeping the 

characteristics of the system

 in mind. 

The  combination  of  the  length  of  the  tubing,  the  diameter  of  the  tubing,  the  flow  rate  of  the 
diesel  fuel  and  the  line  accessories  installed  can  create  back  pressure 

greater  than  the 

maximums  anticipated

  such  as  to  cause  the  (partial)  opening  of  the  pump  by-pass with  the 

consequent noticeable reduction of the flow rate supplied.

In  such  cases

,  to  allow  correct  functioning  of  the  pump, 

it  is  necessary  to  reduce  system 

resistance

,  using  shorter  tubing  and/or  of  wider  diameter  and  line  accessories  with  less 

resistance (e.g., an automatic dispensing nozzle for greater flow rates).

SUCTION

E 80 / E120 pumps are self-priming and characterized by good suction capacity.
During the start-up phase, with an empty suction tube and the pump wetted with fluid, the electric 
pump unit is capable of suctioning the liquid with a maximum difference in height of 2 meters. 
It is important to point out that the priming time can be as long as one minute and the presence 
of an automatic dispensing nozzle on the delivery line prevents the evacuation of air from the 
installation, and, therefore, prevents proper priming.
For this reason, it is always advisable to prime the pump without an automatic delivery nozzle, 
verifying  the  proper  wetting  of  the  pump.  The  installation  of  a  foot  valve  is  recommended  to 
prevent  the  emptying  of  the  suction  tube  and  keep  the  pump  wet.  In  this  way,  the  pump  will 
subsequently always start up immediately.
When  the  system  is  functioning,  the  pump  can  work  with  pressure  at  the  inlet  as  high  as 
0.5  bar,  beyond  which  cavitation  phenomena  can  begin,  with  a  consequent  loss  of  flow  rate 
and increase of system noise.
As  we  have  said  up  to  this  point,  it  is  important  to  guarantee  low  suction  pressure  by  using 
short  tubing  of  a  diameter  equal  to  or  larger  than  recommended,  reducing  curves  to  a 
minimum  and  using  suction  filters  of  wide  cross-section  and  foot  valves  with  the  lowest 
possible resistance.
It  is  very  important  to  keep  the  suction  filters  clean  because,  once  clogged,  they  increase 
system resistance.
The difference in height between the pump and the fluid level must be kept as small as possible 
and, at any rate, within the 2 meters anticipated for the priming phase.
If this height is exceeded, it will always be necessary to install a foot valve to allow for the filling of 
the suction tube and provide tubing of wider diameter. It is recommended that the pump not be 
installed at a difference in height greater than 3 meters.

Before connection, make sure that the tubing and the suction tank are free of dirt and thread 
residue that could damage the pump and its accessories.
Before connecting the delivery tube, partially fill the pump body with diesel fuel to facilitate 
priming.
Do  not  use  conical  threaded  joints  that  could  damage  the  threaded  pump  openings  if 
excessively tightened.

- Minimum recommended nominal diameter:

- Nominal recommended pressure:
- Use tubing suitable for functioning under suction pressure

1-1/4” (model E80)
1-1/2” (model E120)
10 bar

SUCTION TUBING

- Minimum recommended nominal diameter:
- Nominal recommended pressure:

1”
10 bar

DELIVERY TUBING

In the priming phase the pump must blow the air initially present in the entire installation out of 
the delivery line.
Therefore it is necessary to keep the outlet open to permit the evacuation of the air.

PROBLEMS AND SOLUTIONS

M

The curve refers to the following operating conditions:

Fluid:                              
Temperature:
Suction conditions: 

Under different suction conditions higher pressure values can be created that reduce 
the flow rate compared to the same back pressure values.

To  obtain  the  best  performance,  it  is  very  important  to  reduce  loss  of  suction 
pressure as much as possible by following these instructions:
• Shorten the suction tube as much as possible
• Avoid useless elbows or throttling in the tubes
• Keep the suction filter clean
• Use a tube with a diameter equal to, or greater than, indicated (see Installation)

Diesel fuel
20°C
The  tube  and  the  pump  position  relative  to  the  fluid  level  is 
such  that  a  pressure  of  0.3  bar  is  generated  at  the  nominal 
flow rate.

!   

WARNING

F.3  WORKING CYCLE

The pumps are designed for continuous use under conditions of maximum back pressure.

!   WARNING

Functioning  under  by-pass  conditions  is  only  allowed  for  brief  periods  of  time 
(2-3 minutes maximum).

F.1  ENVIRONMENTAL CONDITIONS

TEMPERATURE:

min. -20°C / max. +60°C

RELATIVE HUMIDITY:

max. 90%

!   WARNING

The temperature limits shown apply to the pump components and must be respected 
to avoid possible damage or malfunction.

!   WARNING

It is the installer's responsibility to use tubing with adequate characteristics.

The  use  of  tubing  unsuitable  for  use  with  Diesel  fuel  can  damage  the  pump,  injure 
persons and cause pollution. 
Loosening  of  the  connections  (threaded  connections,  flanging,  gasket  seals)  can 
cause serious ecological and safety problems..
Check all the connections after the initial installation and on a daily basis after that.
Tighten the connections, if necessary.

!   WARNING

It is the installer's responsibility to provide the line accessories necessary for the safe 
and proper functioning of the pump.
The  use  of  accessories  unsuitable  for  use  with  diesel  fuel  can  damage  the  pump, 
injure persons and cause pollution..

!   WARNING

Verify that the terminal strip blades are positioned according to the diagram provided 
for the available power supply voltage.

Verify  the  correct  direction  of  rotation  of  the  motor  (see  the  paragraph  OVERALL 
DIMENSIONS),  and,  if  not  correct,  invert  the  connection  of  the  two  cables  in  the 
power supply plug or on the terminal strip.

!   

WARNING

Extreme  operating  conditions  can  raise  the  motor  temperature  and,  consequently, 
cause the thermal protection switch to stop it.

Turn off the pump and wait for it to cool before resuming use.

The thermal protection automatically turns off when the motor is sufficiently cool.

!   

WARNING

If  an  automatic  type  dispensing  nozzle  is  installed  on  the  end  of  the  delivery  line, 
the evacuation of the air will be difficult because of the automatic stopping device that 
keeps the valve closed when the line pressure is too low. 
It is recommended that the automatic  dispensing nozzle be temporarily disconnected 
during the initial start-up phase.

F.2  ELECTRICAL POWER SUPPLY

Depending  on  the  model,  the  pump  must  be  supplied  by  a  single-phase  alternating 
current  line  whose  nominal  values  are  shown  in  the  table  in  Paragraph  E.2  -  ELECTRICAL 
SPECIFICATIONS.. 
The maximum acceptable variations from the electrical parameters are:

Voltage:         +/- 5% of the nominal value
Frequency:    +/- 2% of the nominal value

!   WARNING

Power  from  lines  with  values  outside  the  indicated  limits  can  damage  the 
electrical components.

!   WARNING

Always check that the revision level of this manual coincides 
with what is shown on the identification plate.

000305000

YEAR 2008

E80/M

PIUSI SPA
46029 SUZZARA (MN)
ITALY

Condenser: 450V - 16

m

F

1400 rpm

READ INSTRUCTIONS M0064

230 V

50 Hz

500 W

3.5 A

PRODUCT

CODE

PRODUCTION

YEAR

TECHNICAL

DATA

MANUAL

MODEL

Functioning

point

Model

E 80

80

0.6

E 120

110

0.5

E 80

75

1.9

E 120

105

2.5

E 80

0

2.2

E 120

0

2.8

Flow rate

Typical delivery configuration

Delivery closed

4

 m

e

te

rs

 o

1

” 

tu

b

e

K

3

3

/K

4

4

 m

e

te

r

M

a

n

u

a

d

is

p

e

n

s

in

g

n

o

z

z

le

P

A

8

0

 a

u

to

m

a

ti

c

d

is

p

e

n

s

in

g

 n

o

z

z

le

P

A

1

2

0

 a

u

to

m

a

ti

c

d

is

p

e

n

s

in

g

 n

o

z

z

le

Back

pressure

A

(Maximum

flow rate)

C

(Bypass)

B

(Maximum

back

pressure)

PUMP MODEL

ELECTRICAL POWER

Current

Voltage

(V)

Frequency

(Hz)

Max. absorption (*) 

(Amp)

CURRENT

E80 M

AC

AC

AC

AC

AC

AC

230

230

400

400

110

110

50

50

50

50

60

60

3.5

6

1.6

2.5

10

9.5

E120 M

E80 T

E120 T

E80 110V

E120 110V

(*) Refers to functioning with maximum back pressure.

H.1  DISPOSAL

H.2  PRELIMINARY INSPECTION

Check that the machine has not suffered any damage during transport or storage.

Make sure that the motor shaft turns freely.

Clean the inlet and outlet openings, removing any dust or residual packing material.

Check that the electrical specifications correspond to those shown on the identification plate.

H.3  POSITIONING THE PUMP

The pump can be installed in any position (pump axis vertical or horizontal).

Attach  the  pump  using  screws  of  adequate  diameter  for  the  attachment  holes  provided  in 
the  base  of  the  pump  (see  the  section  "OVERALL  DIMENSIONS"  for  their  position  and 
dimension).

!   WARNING

THE MOTORS ARE NOT OF AN ANTI-EXPLOSIVE TYPE. 
Do not install them where inflammable vapors can be present.

SINGLE-PHASE MOTORS

Three-phase motors

 are supplied with a terminal strip box and terminal strip.

To  connect  the  electric  motor  to  the  electric  power  line,  open  the  terminal  strip  cover  and 
connect the cables according to the diagram.

THREE-PHASE MOTORS

A lack of electric power, with the consequent accidental stopping of the pump, can be caused 
by:

- A safety device tripping

- A drop in line voltage

In either case, act as follows:

LACK OF ELECTRIC POWER:

TO MOTOR

TO

MOTOR

C

O

N

D

EN

S

ER

THREE PHASE

A.C. LINE

SINGLE PHASE

The  pumps  are  supplied  without  electrical  safety  equipment  such  as  fuses,  motor 
protectors,  systems  to  prevent  accidental  restarting  after  power  failures  or  others. 
It is indispensable to install an electric panel, upstream from the pump's power supply 
line, equipped with an appropriate residual current operated circuit breaker.

It  is  the  installer's  responsibility  to  perform  the  electrical  connections  with  respect 
for the applicable regulations.

!   WARNING

During installation and maintenance, make sure that the electric supply lines are not live.

Use cables characterized by the minimum cross-sections, nominal voltages and wiring-type 
adequate  to  the  electrical  characteristics  shown  in  Paragraph  E.2  -  ELECTRICAL 
SPECIFICATIONS and the installation environment..

In three-phase motors verify the correct direction of rotation (see Paragraph Q - DIMENSIONS 
AND WEIGHTS).

All  motors  are  equipped  with  a  ground  terminal  to  connect  to  the  ground  line  of  the 
electrical network.

Always  close  the  cover  of  the  terminal  strip  box  before  supplying  electrical  power, 
after  ascertaining  the  integrity  of  the  gasket  seals  that  ensure  protection 
grade IP 55.

• 

Check  that  the  quantity  of  diesel  fuel  in  the  suction  tank  is  greater  than  the  amount  you 
wish to transfer.

Make  sure  that  the  residual  capacity  of  the  delivery  tank  is  greater  than  the  quantity  you 
wish to transfer.

Do not run the pump dry. This can cause serious damage to its components.

Make  sure  that  the  tubing  and  line  accessories  are  in  good  condition.  Diesel  fuel  leaks 
can damage objects and injure persons.

Always install a suction filter to protect the pump.

Never start or stop the pump by inserting or removing any plugs.

Do not operate switches with wet hands.

Prolonged  contact  with  diesel  fuel  can  damage  the  skin.  The  use  of  glasses  and  gloves 
is recommended.

Single-phase motors are provided with an automatic thermal protection switch.

• 

Respect  the  following 

(not  exhaustive)

  instructions  to  ensure  a  proper  electrical 

installation:

INITIAL START-UP

I

The  priming  phase  can  last  from  several  seconds  to  a  few  minutes,  as  a  function  of 
the characteristics of the system. 

If this phase is prolonged, stop the pump and verify:

When priming has occurred, verify that the pump is operating within the anticipated range, 
in particular:

That the pump is not running completely dry;

That the suction tubing is not allowing air to seep in;

That the suction filter is not clogged;

That  the  suction  height  is  not  greater  than  2  meters  (if  the  height  is  greater  than  2  meters, 
fill the suction tube with fluid);

That the delivery tube is allowing the evacuation of the air.

That  under  conditions  of  maximum  back  pressure,  the  power  absorption  of  the  motor 
stays within the values shown on the identification plate;

That the suction pressure is not greater than 0.5 bar;

That  the  back  pressure  in  the  delivery  line  is  not  greater  than  the  maximum  back  pressure 
anticipated for the pump.

On a weekly basis, check that the tubing joints have not loosened, to avoid any leakage.

On a monthly basis, check the pump body and keep it clean of any impurities.

On a monthly basis, check and keep the pump filter clean and any other filters installed.

On a monthly basis, check that the electric power supply cables are in good condition.

a.

b.

c.

d.

e.

f.

If  using  flexible  tubing,  attach  the  ends  of  the  tubing  to  the  tanks.  In  the  absence 
of  an  appropriate  slot,  solidly  grasp  the  delivery  tube  before  beginning 
dispensing.

Before  starting  the  pump  make  sure  that  the  delivery  valve  is  closed  (dispensing  nozzle 
or line valve).

Turn the ON/OFF switch to ON. The by-pass valve allows functioning with the delivery closed 
for only brief periods.

Open the delivery valve, solidly grasping the end of the tubing.

Close the delivery valve to stop dispensing.

When dispensing is finished, turn off the pump.

DAILY USE

L

!   WARNING

Functioning  with  the  delivery  closed  is  only  allowed  for  brief  periods  (2-3  minutes 
maximum). After use, make sure the pump is turned off.

a.

b.

c.

Close the delivery valve

Attach the end of the delivery to the slot provided on the tank

Turn the ON/OFF switch to the OFF position.

Resume  operations  as  described  in  Paragraph  L  -  DAILY  USE,  after  determining  the  cause 
of  the stoppage.

E  80  /  E  120  pumps  are  designed  and  constructed  to  require  a  minimum  of 
maintenance.

MAINTENANCE

N

Under normal working conditions the noise emission from all models does not exceed the value 
of 

70 dB at a distance of 1 meter

 from the electric pump.

NOISE LEVEL

O

MANUALE

D’USO E

MANUTENZIONE

USE AND

MAINTENANCE

MANUAL

ITALIANO

ENGLISH

Bulletin

MOO64C

IT/EN

Rev. 1

H.7  COLLEGAMENTI ELETTRICI

• FIRE - EXPLOSION
• FIRE - EXPLOSION
• MOTOR OVERLOAD
• PUMP OXIDATION
• CONTAMINATION OF THE SAME
• PUMP CORROSION
   INJURY TO PERSONS
• FIRE - EXPLOSION 
   DAMAGE TO GASKET SEALS

European Directive 2002/96/EC requires that the equipment bearing this symbol 
on  the  product  and/or  its  packaging  must  not  be  disposed  of  with  unsorted 
municipal waste. The symbol indicates that this product should be disposed of 
separately from regular household waste streams. 
It  is  your  responsibility  to  dispose  of  this  and  other  electric  and  electronic 
equipment  via  designated  collection  facilities  appointed  by  the  government  or 
local authorities.

DISPOSAL OF OTHER PARTS:

The disposal of other parts such as pipes, rubber seals, plastic components and cables should 
be entrusted to companies that special in the disposal of industrial waste.

DISPOSAL OF PACKAGING:

The packing material does not require special precautions for its disposal, not being in any way 
dangerous or polluting. Refer to local regulations for its disposal.

The components must be given to companies that specialise in the disposal and recycling of 
industrial waste and, in particular, the

DISPOSAL OF PACKAGING:

The packaging consists of biodegradable cardboard which can be delivered to companies for 
normal recycling of cellulose.

DISPOSAL OF METAL COMPONENTS:

Metal  parts,  whether  paint-finished  or  in  stainless  steel,  can  be  consigned  to  scrap  metal 
collectors.

DISPOSAL OF ELECTRIC AND ELECTRONIC COMPONENTS:

these  have  to  be  disposed  by  companies  that  are  specialised  in  the  disposal  of  electronic 
components, in accordance with the instructions of 2002/96/EC (see text of Directive below).

ENVIRONMENTAL  INFORMATION  FOR  CUSTOMERS  IN  THE  EUROPEAN 
UNION

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Check the electrical 
connections and the safety 
systems

Check for possible damage or 
obstruction of the rotating 
components

Bring the voltage back within 
the anticipated limits

Lower the pump with respect 
to the level of the tank or 
increase the cross-section 
of the tubing

Use shorter tubing or of greater 
diameter

High loss of head in the 
circuit (working with the 
by-pass open)

Low rotation speed

Low voltage in the electric 
power line

Wait for the motor to cool, 
verify that it restarts, and 
research the cause of the 
overheating

Contact the Service 
Department

Clean and/or replace the valve

Clean the filter

Refill the tank

Motor problems

Foot valve blocked

Filter clogged

Excessive suction pressure

Low level in the suction tank

By-pass valve blocked

Air entering the pump or the 
suction tubing

A narrowing in the suction 
tubing

The suction tubing is resting on 
the bottom of the tank

Irregular functioning of the
by-pass

Cavitation occurring

Air present in the diesel fuel

Seal damaged

Dismantle the valve, clean 
and/or replace it

Check the seals of the 
connections

Use tubing suitable for working 
under suction pressure

Raise the tubing

Dispense until the air is purged 
from the circuit

Reduce suction pressure

Verify the suction connections

Check and replace the 
mechanical seal

Check the voltage at the pump; 
Adjust the voltage and/or use 
cables of greater cross-section

The motor protecting thermal 
switch has tripped

Lack of electric power

Rotor jammed

THE MOTOR 

IS NOT TURNING

THE MOTOR 

TURNS SLOWLY 

WHEN STARTING

INCREASED 

PUMP NOISE

LEAKAGE FROM THE 

PUMP BODY

LOW OR NO
FLOW RATE

IT  IS  THE  INSTALLER'S  RESPONSIBILITY  TO  APPLY  THE 
FOLLOWING  SIGNALS  ON  THE  MACHINE  ANYWHERE 
E80/E120 WILL BE USED:

!   WARNING

F

lo

w

 r

a

te

Back pressure

C

B

A

the legal representative

The undersigned:

PIUSI S.p.A - Via Pacinotti c.m. - z.i.Rangavino
46029 Suzzara (Mantova) - Italy

 

HEREBY STATES 

under its own responsibility, that the partly-completed machinery:

 

Description: 

Machine designed for the transfer of diesel fuel

Model: 

E80 - E120

Serial number: 

refer to Lot Number shown on CE plate affixed to product

Year of manufacture: 

refer to the year of production shown on the CE plate affixed to the 
product

is intended to be incorporated in a machine (or to be with other machines) so as to create a 
machine to which applies Machine Directive 2006/42/EC, may not be brought into service before 
the machine into which it is to be incorporated has been declared in conformity with the provisions 
of the directive 2006/42/EC. 

is in conformity with the legal provisions indicated in the directives:

- Machine Directive 2006/42/EC 
- Low-Voltage Directive 2006/95/EC 
- Electromagnetic Compatibility Directive 2004/108/EC

To which the essential safety requirements have been applied and complied with what indicated 
on annex I of the machine directive applicable to the product and shown below: 1.1.3 - 1.1.5 - 1.3.1 - 
1.3.2 - 1.3.3 - 1.3.4 - 1.3.8 - 1.4.1 - 1.4.2.1 - 1.5.1 - 1.5.2 - 1.5.4 - 1.5.5 - 1.5.8 - 1.5.11 - 1.6.1 - 1.6.3 - 
1.6.4 - 1.7.1 - 1.7.2 - 1.7.3 - 1.7.4.

The documentation is at the disposal of the competent authority following motivated request at Piusi 
S.p.A. or following request sent to the email address: [email protected]
The person authorised to compile the technical file and draw up 
the declaration is Otto Varini as legal representative.

Suzzara, 29/12/2009

Отзывы: