Page 5
For technical questions, please call 1-800-444-3353.
Item 69926
Maintenance and Servicing
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and disconnect the Battery Clamps before
performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM COMPRESSOR FAILURE:
Do not use damaged equipment. If abnormal noise or vibration occurs,
have the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
1.
BEFORE EACH USE,
inspect the general
condition of the air compressor. Check for:
• loose hardware,
• misalignment or binding of parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may
affect its safe operation.
2.
AFTER USE,
wipe external surfaces of
the compressor with a clean cloth.
3. Store the Air Compressor in a clean, dry,
safe location out of reach of children
and other unauthorized people.
4. If the Fuse needs to be replaced,
unthread the cap on the end of the
Cigarette Lighter Adapter and remove the glass fuse.
Replace the old Fuse with a new Fuse (included
in the inflator nozzle bag), and replace the Cap.
WARNING!
To prevent fire, replace fuse
only with fuse of same type and rating.
Do not replace with any other object.
5.
Maintenance to be performed by a
qualified service technician:
a.
AFTER USING 20 TIMES,
lubricate
the Shaft and Piston Ring.
b.
AFTER EVERY 500 HOURS OF
REGULAR USE
, replace the Compression
Ring and Inlet and Outlet Valves.
Troubleshooting
Problem
Possible Causes
Likely Solutions
Decreased output 1. Not enough air pressure
and/or air flow.
2. Air leaking from loose
housing or connections.
3. Mechanism contaminated.
1. Check for loose connections
.
2. Make sure housing and connections
are properly assembled and tight.
3. Have qualified technician clean and where
possible, lubricate mechanism.
Severe air leakage
(Slight air leakage
is normal,
especially on older
tools)
1. Cross-threaded housing
components.
2. Loose housing.
3. Dirty, worn or damaged valve.
1. Check for incorrect alignment and uneven gaps.
If cross-threaded, disassemble and
replace damaged parts before use.
2. Tighten housing assembly. If housing cannot be
tightened properly, internal parts may be misaligned.
3. Clean or replace valve assembly.
No output
1. Poor connection.
2. Power Switch in Off (O) position.
3. Run-down battery.
4. Blown Fuse.
1. Check that Cigarette Lighter Adapter is completely
inserted into the Cigarette Lighter Socket.
2. Turn Power Switch to On (I) position.
3. Recharge battery.
4. Replace Fuse.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect from battery before service.
Содержание 69926