background image

L20-246 Rev 0 (12/02)

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

CORRECTIVE ACTION

Computer does not come on

A. Main circuit breaker is

A. Locate the correct building circuit breaker

nothing shows in either display

turned off

and turn OFF and back ON again.

B. Fryer fuse is blown

B. Call an Authorized Service Technician

Computer heat light comes on

A. If the oil is hot the

A. Allow the oil to cool, reset the Hi Limit and

but elements do not heat

Hi - Limit may be tripped

turn  the computer OFF and back ON
again.

Computer display shows

A. Bad computer

A. Locate the correct building circuit breaker and

"OFF" and cannot be turned

turn OFF and back ON again. If this does not

"ON".

reset the computer call an Authorized Service
Technician.

RED return valve is open no

A. RED return valve not fully

A. Pull slightly on the RED return valve handle

pump sound can be heard

open

B. Filter circuit breaker may be

B. Locate the filter circuit breaker behind the door

tripped

of the left hand fryer and reset it.

C. Filter motor Thermal Over-

C. Push RED reset button located on end of filter

load may be tripped

motor, behind the door of left hand fryer.

D. Sensor switch may be loose

D. If the mounting screws are loose try to tighten

them, if this is not possible call an Authorized
Service Agency.

Drain valve is closed and

A. GREEN drain valve is not

A. Apply a little more pressure to close the valve

the computer has been

 fully closed

reset but still shows

B. Sensor switch may be loose

B.

If the mounting screws are loose try to tighten

"DRAINING" or

them, if this is not possible call an Authorized

"TURN OFF"

Service Agency.

Drain valve is open, the oil is

A. GREEN drain valve is not

A. Apply a little more pressure to open the valve

draining slowly or not at all.

fully open

B. Drain is plugged with debris

B. Use the clean out rod to clear the drain valve

from inside the fry vat. If this does not clear the
blockage, CLOSE the GREEN drain valve and
follow the instructions for clearing the main
drain line.

                            CAUTION:

Some HOT oil may come out when the cap is
removed.
Remove the two wing nuts from the end cap
(do NOT lose these.) Use the clean out rod to
clear the main drain tube. Install the end cap
along with its gasket and four screws. Do not
overtighten these screws or remove drain "T"
cleanout access covers, by removing thumb
screws (do not loose screws).  Then clean drain,
replace access cover and thumb screws.

         

  9

Содержание SE Series

Страница 1: ...ion Manual For Electric Fryers Covering Models SE SEH Series Pitco Frialator Inc P O Box 501 Jct I 89 I 93 Concord NH 03302 0501 509 Route 3A Bow NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 L20 246 Rev 0 01 03 ENGLISH ...

Страница 2: ...ERVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THIS APPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY AND AS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BY A QUALIFIED TECHNI CIAN ON A YEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECT...

Страница 3: ...terial or workmanship for a period of two years B If the computer is found to be defective dur ing the first 2 years after the installation date Pitco Frialator Inc will also pay for the la bor freight and travel costs involved in re placing said part 4 WARRANTYPROVISIONS ELEMENTS A Pitco Frialator Inc will warrant the Electric Elements from defects in material or work manship for a period of 3 ye...

Страница 4: ... performed by qualified personnel The duct system the hood system and the fryers must be cleaned on a regular basis and must be kept clear of any grease build up Ventilation A proper ventilation system is also an impor tant part of the installation Clearances Minimum clearance of 6 15cm must be maintained from combustible construction on each side and the rear of the equipment This equipment may b...

Страница 5: ...left key for the left side of a split vat computer to turn the unit ON The computer display will light and the heating elements will begin to heat and will be controlled by the computer controller NOTE It is recommended that melt cycle be used This will extend the shortening life In melt cycle the shortening turns from solid to liquid gradually through short controlled bursts of heat Once the pred...

Страница 6: ...d handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank f When bubbles are seen coming out of the oil return spout close the red handled valve to turn the pump off If necessary add more oil to the tank to return the oil level to the fill mark The fryer is now ready for use DRAINING A TANK The filter system is also used to drain...

Страница 7: ...chine is now ready to use ENGLISH 4 PlacethePaperSupportScreeninthebottomofthe pan Place filter Paper or Pad over screen making sure that there is an equal amount of excess paper on each side Place the Retaining Frame on the paper or pad making sure that all edges are being pressed down evenly Slide filter drawer back under fryer making sure that the oil return pipe locates into its mating connect...

Страница 8: ...rain Use the brush to clean the sides of the tank as the oil drains WARNING This filter pan is only large enough to hold the contents of one 1 tank at once during the filter process g When the tank is empty close the green handled drain valve Open the red handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank h When bubbles are ...

Страница 9: ...p bracket from the filter paper support screen and slide the filter paper support screen out of the filter paper clip bracket e Remove filter paper support screen from the filter envelope f All of the filter pick up assembly parts can be washed in a dish washer or a pot sink Flush out the suction tube assembly with hot water After cleaning it is very important to thor oughly dry the parts before r...

Страница 10: ...ture is entered boil mode will start automatically You must turn off both fryers to exit Boil mode After 5 secs machine will return to run mode After 5 secs machine will return to run mode CHECKING THE REMAINING TIME WHEN USING MULTIPLE TIMERS TO VIEW REMAINING TIME ON ANY FUNCTION KEYS WHEN MULTIPLE TIMERS ARE COUNTING IS AS FOLLOWS PRESS THEN PRESS FUNCTION KEY OF ANY NON DISPLAYED ACTIVE TIMERS...

Страница 11: ...L20 246 Rev 0 12 01 ENGLISH 6 ...

Страница 12: ...L20 246 Rev 0 12 02 7 ...

Страница 13: ...L20 246 Rev 0 12 01 ENGLISH 8 ...

Страница 14: ...r behind the door of left hand fryer D Sensor switch may be loose D If the mounting screws are loose try to tighten them if this is not possible call an Authorized Service Agency Drain valve is closed and A GREEN drain valve is not A Apply a little more pressure to close the valve the computer has been fully closed reset but still shows B Sensor switch may be loose B If the mounting screws are loo...

Страница 15: ...L20 246 Rev 0 12 01 10 ENGLISH ...

Страница 16: ...he Pitco Frialator Authorized Service and Parts representative ASAP covering you area or contact Pitco at the numbers listed to the left In the event of problems with or questions about your order please contact the Pitco Frialator fac tory at 800 258 3708 US and Canada only or 603 225 6684 World Wide ...

Отзывы: