9
L22-236 Rev 0 (04/03)
Filter Trouble Shooting
PROBLEM
POSSIBLE CAUSE
ACTION
Red return handle is pulled out, but no
pump sound can be heard
A. Red return handle not completly
open
B. Filter circuit breaker may be tripped
or in the off position
C. Filter motor thermal overload may
be tripped
D. Sensor switch may be loose or
defective
E. Power cord unplugged or loose
A. Pull on red return handle to make sure
valve is completly open
B. Reset the circuit breaker or press it to
the on position
C. Push the red reset button on the end of
the motor
D. Check that the switch is tight and that it
has the correct gap. Replace if defective
E. Check the power cord at the fryer
entrance box and at the pump box and
make sure that the power cords are plugged
in and /or pushed in all the way
Drain valve is closed, computer has
been reset, but computer still displays
"DRAINING"
A. Blue drain valve not fully closed
B. Sensor switch
C. Incorrect switch gap/alignment
A. Check position of handle
B. Switch may be loose or have loose
wires, replace if defective
C. Check gap/alignment, replace if defective
Oil is returning to the vat slowly or not
at all
A. Dirty filter paper
B. Strainer cap dirty
C. Filter pan not pushed in completely
D. O-rings not sealing on pick up tube
A. Change filter paper
B. Remove strainer cap and clean it
C. Push filter pan in
D. Check & replace if defective
Air bubbles are in the oil being returned
to the vat
A. Strainer cap not tight
B. Stainer cap not in pick up tube
C. Filter pan not pushed in completely
D. O-rings not sealing on pick up tube
A. Tighten strainer cap
B. Install strainer cap
C. Push filter pan in
D. Check & replace if defective
Drain valve is open, the oil is draining
slowly or not at all
A. Drain valve is not fully open
B. Drain line is plugged with debris
A. Apply a little more pressure to the drain
valve handle to check that the drain valve is
fully open
B. Use the clean out rod to clear the drain
valve opening. If this does not clear the
blockage, close the drain valve, and call for
service
Содержание MG2 Full
Страница 12: ...12 L22 236 Rev 0 04 03 Schematics...
Страница 20: ...20 L22 236 Rev 0 04 03 Exploded Drawings and Parts Lists...
Страница 23: ...23 L22 236 Rev 0 04 03 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 Figure 1...
Страница 27: ...27 L22 236 Rev 0 04 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Figure 3...