background image

Spin Fryer I12 Cooking Computer 
Pitco P/N 60149505 

L22-355 Rev 1 

Page 22 of 28 

 

5.11 Test 

On/Off 

With display showing 

 press product key 

0

Display shows [TEST xx], where “xx” is ON or OFF.  If ON is selected, temperatures 
displayed by the controller are probe tip temperatures unaltered by values set in 
section 4.1, or 5.1

.  For normal operations, this setting should remain OFF

To change this value, use product key 0 to toggle choice (ON or OFF). 

Press the 

 key. Display now shows 

 

 

 

5.12  More Factory Menu Entry 

With display showing 

 press product key 

R

Display shows 

 

R

 

5.12.1  Control ID Display 

From the 

 display, press the [0] key. 

Display will show [CONTROL ] [60149505], the Pitco part number, 60149505. 

Press the [0] key again. 

Display will show [S/W           ] [0149501x], this is Pitco’s software number and current 
revision letter.   

 

Press the [0] key again. 

Display will show [CHECKSUM] [00Fxxxxx], the software check sum of the loaded 
software. 

 

Press the [0] key again to repeat these items, or, press 

 to return to 

 

5.12.2 Set 

Network 

Address 

This menu is identical to Set Network Address section 4.8.9 except 

 is 

displayed instead of [SERVICE].   

 

 

5.13  To Exit Factory Menu (Level 4): 

 

To exit Factory Programming, Press the 

 key.  Display will show 

Continue with settings in section 2 or 3, or exit in the next step. 

 

To return to normal operations, press the 

 key again. 

 

Display shows

 

, or 

0

0

R

Содержание L22-355

Страница 1: ...rogrammed with cook shake and hold times to keep pace with changing menus over time This manual details the operation and adjustment of the Spin Fryer I12 Cooking Computer control The target audience...

Страница 2: ...ager 10 3 1 Fahrenheit or Celsius Display ___________________________________________________ 10 3 2 Password Change or Required _________________________________________________ 10 3 3 Beeper ON OFF...

Страница 3: ..._______ 20 5 7 Ready Level _________________________________________________________________ 20 5 8 Operating Temperature Range___________________________________________________ 20 5 9 High Limit Val...

Страница 4: ...isplays Wait for the appliance to heat up to the READY condition before cooking 1 2 To turn the appliance OFF Press the key Display will momentarily show the software version number and then 1 3 To st...

Страница 5: ...show CKn mm ss followed by SHn mm ss then HDn mm ss ending with PA4 mm ss Where n is the key number and mm ss is the time setting After a few moments the display will return to or or CKn mm ss for any...

Страница 6: ...pt Pressing the 0 key is a YES response to the boil prompt If pressed display will show Heat will maintain vat temperature at 185 F 85 C for cleaning as long as the control remains on To exit boil mod...

Страница 7: ...one of the following displays or Press the key If display shows a password is required Enter password Level 1 2Password 6 8 6 4 using the product keys as a numeric keypad for entry With correct passwo...

Страница 8: ...alue is zero meaning the Shake Time is inactive To use Shake Time the time value must be a non zero value and must be set to a value less than cook time Display shows nSH mm ss TIME where n is the key...

Страница 9: ...ill not spin after a cook cycle if the set spin time is set to 0 Display shows nST mm ss TIME where n is the key number ST means Spin Time and mm ss is minutes and seconds Use the product keys for num...

Страница 10: ...Display shows Press product key 1 display shows DEGREE n F OR C where n is the current setting Use the product key 0 to scroll through choices F or C Press key to save choice Display shows 3 2 Passwo...

Страница 11: ...ow Press product key 4 display shows ENGLISH LANGUAGE Use the product key 0 to scroll through choices ENGLISH ESPANOL FRANCAIS DEUTSCH HOLLAND Press key to save choice Display shows 3 5 Melt Cycle Typ...

Страница 12: ...increased recovery times stored in this display There is no selection done here just the display of recovery time values With display showing press the product key 0 Display will show Press product k...

Страница 13: ...the probe temperature With display showing press product key 1 Display shows OFF nn F DEGREES where nn is the value of the adjustment Negative values are preceded with a minus sign To change this val...

Страница 14: ...Use the product keys for numeric entry of a new value Press the key Display now shows 3 4 4 Recovery Times This controller maintains a record of heat up times for the appliance A poorly running appli...

Страница 15: ...ake Toggles basket lift brake output on and off Display will show Brake Brake 2 4 5 3 Heat Demand Output Hold the product key 3 to force Heat Demand output ON Display will show HEAT DEM Releasing the...

Страница 16: ...380 No adjustments are permitted here This is an information display only Press the key Display returns to 7 4 8 More Service Menu Entry With display showing press product key 8 to enter submenu Displ...

Страница 17: ...lue then press the to save choice Display returns to 4 8 4 Hold Alarm Duration With the display showing press product key 5 Display will show HD DUR nn DURATION where nn is the time in seconds the hol...

Страница 18: ...is off Note Heat Demand Profile section 4 8 3 must be set to Generic 1 or T stat Standing Pilot toggle has no effect in with any other setting With the display showing press product key 9 Display will...

Страница 19: ...wing press product key L Display shows PCOLLECT OFF This toggle forces the RS 485 link to output data collection parameters during test and calibration This has no meaningful use in the field Note Do...

Страница 20: ...xcept is displayed instead of SERVICE 5 8 Operating Temperature Range This menu is identical to Temperature Operating Range section 4 7 except is displayed instead of SERVICE 5 9 High Limit Value With...

Страница 21: ...aximum of 500 RPM 1 5 10 3 Motor Speed Decrease Decreases the spin motor s speed in 10 RPM increments up to a minimum of 60 RPM 2 5 10 4 Spin Direction Toggles the motor s spin direction from spinning...

Страница 22: ...ntrol ID Display From the display press the 0 key Display will show CONTROL 60149505 the Pitco part number 60149505 Press the 0 key again Display will show S W 0149501x this is Pitco s software number...

Страница 23: ...value Display will show TURN OFF Turn controller off and refill the vat Continue with normal operations at section 1 This message indicates that the heating system failed to respond Typically the hig...

Страница 24: ...ransformer Display will show an alternating message SM_POSIT FAILURE This message indicates that the basket lift was unable to detect the target position during operational basket lift movement Basket...

Страница 25: ...Spin Fryer I12 Cooking Computer Pitco P N 6049505 L22 280 Rev 1 25 of 28 7 Mechanical Dimensions...

Страница 26: ...N PWR 24VACN 24VAC Return 3 PROBE 4 PROBE 5 DVI IN 24VAC Drain Valve Interlock 6 HFB IN 24VAC Heat Feed Back 7 24VDC COM IN 24VDC DC Returm 8 HD OUT 24VDC Heat Demand 9 SO xFER OUT 24VDC Side ON or XF...

Страница 27: ...96 65 18 3 122489 230 110 0 4675 395 201 7 576 09 70 21 1 108051 235 112 8 4329 400 204 4 547 09 75 23 9 95539 240 115 6 4013 405 207 2 519 86 80 26 7 84644 245 118 3 3723 410 210 0 494 24 85 29 4 75...

Страница 28: ...lator factory at 603 225 6684 World Wide www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative AS...

Отзывы: