PREVENTATIVE MAINTENANCE  

 

11 

L20-259, rev. 8 (04/15) 

WARNING 

The power supply must be disconnected before cleaning and servicing this appliance! 

3.3. ANNUAL/PERIODIC 

PREVENTATIVE MAINTENANCE AND INSPECTION 

This section should ONLY be performed by a qualified service technician as part of a regular kitchen 
maintenance program.  This inspection should take place a minimum of once a year by an Authorized 
Service Technician recommended by Pitco. 
 
 
 
 

 

3.3.1. HEATING 

ELEMENT 

  Check if the element is mechanically sound and in good condition.  Look for scale build up 

and inspect for signs of repeated dry firing. 

  Verify element wires are in good working condition.  Look for damage to wires or frayed 

insulation.  Check that the insulation is dry. 

  Verify that bulkhead connections/nut is tight and leak free. Look for water stains and wet 

surfaces. 

  Verify amp-draw is within range as compared to the information on the data plate. 

 

3.3.2.  TEMPERATURE PROBE & HIGH LIMIT PROBE 

  Verify probes are in good working condition.  Check for damage and that the fasteners are 

tightly secured to the tank. 

  Verify compression fittings are leak free. 

  Check wiring for loose electrical connections. 

 

3.3.3.  LOW WATER LEVEL SENSOR 

  Verify contacts are clean and free of damage. 

  Verify that the contacts are properly secured, contacts should not rotate. 

  Verify there are no water leaks around the contact fluropolymer washers. 

 

3.3.4. CONTROLLER 
Perform the following inspection if the appliance is equipped with a temperature controller. 

  Verify that the controller is in good mechanical condition.  Check all lights, displays and 

switches to assure that they are working properly.  Examine overlay for damage that could 
allow moisture to enter. 

  Check for loose electrical connections. 

  Verify set temperature.  Check temperature 1” above controller probe, if necessary check 

probe resistance. 

 

3.3.5.  CONTROL BOX & ELECTRICAL COMPONENTS 

  Verify that heating contactors are in good condition.  Check for worn or pitted contacts.  Verify 

that wires are tight and in good condition. 

  Verify that all components (transformer, terminal block, relays, drain switches, etc…) are in 

good condition.  Verify that wires are tight and in good condition. 

  Verify enclosures are free of leaks.  Check for water stains and wet surfaces. 

  Verify that the covers and panels are in tact and provide a safe condition.  Check for loose 

parts. 

  Verify power cord is in good condition.  Check for frayed or exposed wires.  Verify that the 

insulation is in good condition and the attachment to the appliance is tight. 

 

3.3.6. TANK 

  Verify that the tank is in good condition.  Check for scale build up and inspect for signs of 

corrosion.  Verify that tank is leak free.  Check drain overflow (if equipped) for scale build up 
and debris blockage. 

 

3.3.7. DRAIN 

SYSTEM 

  Verify that drain valve is in good condition.  Check for leaks in the seal area and fitting region. 

 

Verify that drain lines are leak free, kink free and in good condition.  Check for scale build up 
and debris blockage.  Verify that the clamps and connections are securely tightened.

 

 

 

Содержание CRTE

Страница 1: ...se complete this information and retain this manual for the life of the equipment Model ___________________________ Serial ___________________________ Date Purchased ____________________ ENGLISH Insta...

Страница 2: ...on the appliance to accommodate placement under a ventilation hood WARNING This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or...

Страница 3: ...3 2 COOKING TIPS 9 2 4 APPLIANCE SHUTDOWN 9 3 PREVENTATIVE MAINTENANCE 10 3 1 DAILY PREVENTATIVE MAINTENANCE 10 3 1 1 APPLIANCE INSPECTION 10 3 1 2 CLEANING THE COOK TANK 10 3 1 3 CLEANING THE CABINET...

Страница 4: ...nd serial number on the inner door of the appliance and the find the date purchased Write this information on the front cover of this manual for future reference If you have completed the above steps...

Страница 5: ...ain hose must be inserted into the tank quick disconnect fitting before the appliance can drain correctly Drain connections for this appliance are to be made at the end of the 36 91 44 cm long drain h...

Страница 6: ...tions WARNING The appliance must be grounded in accordance with local code if there is no local code comply with the NEC and ANSI NFPA No 70 latest edition for US and Canadian installations In all oth...

Страница 7: ...e listing above Available Power Cords Description Standard Hubbell Mates to 1 Twist Lock NEMA L6 30P HBL2621 HBL2620 2 Shrouded Twist Lock NEMA L6 30P HBL2621S HBL2626 3 Right Angle Straight Blade NEM...

Страница 8: ...d operating the appliance perform the following visual checks After the appliance is in its permanent location check to ensure that it is level Any additional leveling that is necessary can be perform...

Страница 9: ...down to remove any dust or foreign matter that may have accumulated during shipment of the appliance 5 When cleaning is complete rinse the inside of the tank thoroughly with cool water Continue to rin...

Страница 10: ...ch will interrupt power to the element if the internal cook tank reaches an unsafe temperature This is to protect the appliance in the event the water is drained from the tank while the unit is on or...

Страница 11: ...3 2 COOKING TIPS Always follow the food manufacturer s directions and only use sealed bagged products in this appliance Some products can be reheated and held at the same temperature If this is the ca...

Страница 12: ...nd sanitizing food contact surfaces Follow the directions and familiarize yourself with the safe use of this cleaner prior to using it to clean the appliance Care must be taken to remove all the forei...

Страница 13: ...ollowing inspection if the appliance is equipped with a temperature controller Verify that the controller is in good mechanical condition Check all lights displays and switches to assure that they are...

Страница 14: ...5 Restart the appliance by pressing the power switch to the position and releasing 4 3 LIQUID LEVEL CONTROL This appliance is equipped with a Liquid Level Control The level control will stop the appl...

Страница 15: ...lease Power cord disconnected Check power cord connection High temperature limit tripped Allow the appliance to cool to room temperature and the high limit switch will auto reset Low water level Fill...

Страница 16: ...CRTE COUNTER TOP RETHERMAILZER TROUBLESHOOTING L20 259 rev 8 04 15 14 4 6 PROGRAMMING INSTRUCTIONS...

Страница 17: ...TROUBLESHOOTING 15 L20 259 rev 8 04 15 PROGRAMMING Cont d...

Страница 18: ...CRTE COUNTER TOP RETHERMAILZER TROUBLESHOOTING L20 259 rev 8 04 15 16 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...TROUBLESHOOTING 17 L20 259 rev 8 04 15 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 20: ...t 603 225 6684 World Wide Website Address www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative A...

Отзывы: