19
again before resuming motion detection for next detector.
Move away from the area that is in direct line of sight of the Motion
Sensor (move to an adjacent room). Wait 60 seconds until the LED
stops blinking.
Move back into the line of sight of the Motion Sensor, walk around 3-5
steps. (this will trigger the main console).
If the Motion Sensor test is successful the LCD screen will display " xxx
Sensor Alarm". If these words do not appear, either (A) the 20-second
waiting period since the last trigger has not expired, or (B) the Motion
Sensor is not in communication with the PiSECTOR system main
console.
If you want to re-start the Walk Test mode again, open the Front Cover
as shown in Figure 1 and then re-attach the Front Cover.
Mount Motion Sensor
Place the motion sensor
following
the
location
recommendations (check
marked locations) shown
in Figure C. Avoid the
example location marked with the "X" which are household areas that
typically cause false alarms, such as heat, air conditioning, fans, or
direct sunlight. The recommended mounting height is 6.5-7.0 feet for
both coverage and pet immunity purposes.
Apply the 3M adhesive tape in the locations
shown in Figure D for corner mounting or wall
mounting.