PISCO VN Series Скачать руководство пользователя страница 3

192

Vacuum Generator 

VN

 & External Vacuum Controller 

VNP

 Series

VN

M

odel 

D

esignation of vacuum generator alone (

E

xample)

4

(3)

4

(4)

D24

(6)

H05

(1)

4

(2)

S

(5)

V1

(7)

(4) Air supply port for blow-off (PS)

Port type

Straight tube fitting

Code

3

4

N

Size

ø3

mm

ø4

mm

Common to vacuum making air and release air

* For the port of 

ø

3

 and 

ø

4

, vacuum making air and blow-off are indivisually supplied.

(2) Vacuum port (V)

Port type

Straight tube fitting

Elbow tube fitting

Code

3

4

3L

4L

Size

ø3

mm

ø4

mm

ø3

mm

ø4

mm

(1) Vacuum characteristics

Code

Nozzle dia.

Pressure supply

Final vacuum

Suction flow

Air consumption

(in.)

(mm)

(psi)

(MPa) (-in. Hg) (-kPa) (SCFM) (

l

/min[ANR]) (SCFM) (

l

/min[ANR])

E04

ø0.016

ø0.4

50.8

0.35

26.7

90.4

0.07

2

0.21

6

H05

ø0.02

ø0.5

72.5

0.5

0.25

7

0.40

11.5

E05

50.8

0.35

0.11

3

0.28

8

H06

ø0.024

ø0.6

72.5

0.5

0.33

9.5

0.56

16

E06

50.8

0.35

0.18

5

0.42

12

* The flow rate in SCFM is a reference value converted by multiplying 

l

/min[ANR] by 

0

.

035

.

(3) Air supply port for vacuum generation (PV)

Port type

Straight tube fitting

Code

3

4

Size

ø3

mm

ø4

mm

(5) Exhaust port (EX)

Code

S

J

 *

Type

Silencer vent

Tube exhaust type

* Only 

ø

6

mm tube fitting is attached to the exhaust port.

(6) Voltage specification

Code

D24

Spec.

24VDC

(7) Sensor specifications

Code

Speãfications

No code

Without sensor

V1

Analog vacuum sensor

V2

Separated LED indi Analog vacuum sensor

R1

Analog compound pressure sensor

R2

Separated LED ind Analog compound pressure sensor

VNB

M

odel 

D

esignation of unit bracket (option)

* Attached with two hexagon socket head screw (M

3

×

12

).

VN012B33

M

odel 

D

esignation of silencer element (maintenance parts) for vacuum generator alone

VN

M

odel 

D

esignation of vacuum generator manifold type (

E

xample)

4

(3)

4

(4)

D24

(6)

H05

(1)

4

(2)

S

(5)

V1

(7)

M 08

(8)

(4) Air supply port for blow-off (PS)

Code

Fitting size & type

Both side R side only L side only

4

4R

4H

ø4

mm straight tube fitting

6

6R

6H

ø6

mm straight tube fitting

8

8R

8H

ø8

mm straight tube fitting

4L

4LR

4LH

ø4

mm elbow tube fitting

6L

6LR

6LH

ø6

mm elbow tube fitting

8L

8LR

8LH

ø8

mm elbow tube fitting

N

Common to vacuum making air and blow-off air

* When the port codes of 

4

6

8

4

L, 

6

L and 

8

L are selected, vacuum making air and blow-off air are individisually 

supplied.

(2) Vacuum port (V)

Port type

Straight tube fitting

Elbow tube fitting

̶

Code

3

4

3L

4L

K

Size

ø3

mm

ø4

mm

ø3

mm

ø4

mm

For a combination of different sensors (*

1

)

*

1

Give details in the specification order form

(1) Vacuum characteristics

Code

Nozzle dia.

Pressure supply

Final vacuum

Suction flow

Air consumption

(in.)

(mm)

(psi)

(MPa) (-in. Hg) (-kPa) (SCFM) (

l

/min[ANR]) (SCFM) (

l

/min[ANR])

E04

ø0.016

ø0.4

50.8

0.35

26.7

90.4

0.07

2

0.21

6

H05

ø0.02

ø0.5

72.5

0.5

0.25

7

0.40

11.5

E05

50.8

0.35

0.11

3

0.28

8

H06

ø0.024

ø0.6

72.5

0.5

0.33

9.5

0.56

16

E06

50.8

0.35

0.18

5

0.42

12

K

For a combination of different nozzles (give details in the specification order form)

* K: E type and H type can not be mounted on same manifold.  Only nozzles with same vacuum characteristics H or E, 

but different nozzle size, can be mounted together.

* The flow rate in SCFM is a reference value converted by multiplying 

l

/min[ANR] by 

0

.

035

.

(3) Air supply port for vacuum generation (PV)

Code

Fitting size & type

Both side R side only L side only

4

4R

4H

ø4

mm straight tube fitting

6

6R

6H

ø6

mm straight tube fitting

8

8R

8H

ø8

mm straight tube fitting

4L

4LR

4LH

ø4

mm elbow tube fitting

6L

6LR

6LH

ø6

mm elbow tube fitting

8L

8LR

8LH

ø8

mm elbow tube fitting

(5) Exhaust port (EX)

Code

S

Type

Silencer vent

* Tube exhaust type is not selectable for manifold type.

(6) Voltage specification

Code

D24

Spec.

24VDC

(7) Sensor specifications

Code

Speãfications

No code

Without sensor

V1

Analog vacuum sensor

V2

Separated LED indi Analog vacuum sensor

R1

Analog compound pressure sensor

R2

Separated LED ind Analog compound pressure sensor

K

For a combination of different sensors (give details in the specification order form)

Straight type

(8) No. of manifolds 

Code

02

03

04

05

06

07

08

09

10

No. of manifold

2

3

4

5

6

7

8

9

10

Elbow type

Straight type

Elbow type

Vacuum port (V)

Vacuum port (V)

Air supply port for

vacuum generation (PV)

Air supply port for

blow-off (PS)

Air supply port for

vacuum generation (PV)
Air supply port for

blow-off (PS)

2011̲vacuum-4

11.8.4, 3:38 PM

192

Содержание VN Series

Страница 1: ...um Generator VN External Vacuum Controller VNP Series Complex Vacuum Generator External Vacuum Controller for High Speed Stable Response Characteristics Perfect for use in an IC chip loader IC handlers and other semiconductor manufacturing devices Limited space can be utilized Small size and lightweight vacuum generator external vacuum controller In particular the height is lowered for small space...

Страница 2: ...ltage rating 24VDC Allowable voltage range 10 Surge limiting circuit equipped with surge noise filter Power consumption On start up 2 2W On retention 0 6W equipped with power saving circuit Operation indicator Green LED Operating pressure range 0 79 8psi 0 0 55MPa 0 79 8psi 0 0 55MPa 0 29 6in Hg 100 0kPa 0 79 8psi 0 0 55MPa Valve type Normally closed type Response time Max 5msec at vacuum generati...

Страница 3: ...8mm elbow tube fitting N Common to vacuum making air and blow off air When the port codes of 4 6 8 4L 6L and 8L are selected vacuum making air and blow off air are individisually supplied 2 Vacuum port V Port type Straight tube fitting Elbow tube fitting Code 3 4 3L 4L K Size ø3mm ø4mm ø3mm ø4mm For a combination of different sensors 1 1 Give details in the specification order form 1 Vacuum charac...

Страница 4: ...L side only 4 4R 4H ø4mm straight tube fitting 6 6R 6H ø6mm straight tube fitting 8 8R 8H ø8mm straight tube fitting 4L 4LR 4LH ø4mm elbow tube fitting 6L 6LR 6LH ø6mm elbow tube fitting 8L 8LR 8LH ø8mm elbow tube fitting N Common to vacuum making air and blow off air 1 Vacuum port V Port type Straight tube fitting Elbow tube fitting Code 3 4 3L 4L K Size ø3mm ø4mm ø3mm ø4mm For a combination of d...

Страница 5: ...L left side with the vacuum port to one side Vacuum port Air supply port for vacuum generation PV Air supply port for blow off PS St 1 St 2 St 4 Vacuum generator type Vacuum characteristics Vacuum port V Airsupplyportfor vacuumgeneration PV Air supply port for blow off PS Exhaust port EX Voltage Sensor No of manifold VN D24 External vac controller type Vacuum port V Vacuum supply port PV Air suppl...

Страница 6: ...r type Vacuum characteristics Vacuum port V Airsupplyportfor vacuumgeneration PV Air supply port for blow off PS Exhaust port EX Voltage Sensor No of manifold VN D24 External vac controller type Vacuum port V Vacuum supply port PV Air supply port for blow off PS Voltage Sensor No of manifold VNP D24 L side St 1 St 2 Station No St 3 St 4 St 5 St 6 St 7 St 8 R side St 9 St 10 2011 vacuum 4 11 8 4 3 ...

Страница 7: ...may result in lead wires or connector components broken 2 Compressed air contains plenty of drain Water oxidized oil tar and foreign particles etc Since drain may cause performance drop conduct air dehumidification by the after cooler and drier then improve of air quality 3 Never supply lubricated air 4 Rust and inflow of foreign particles in piping cause malfunction and performance drop Therefore...

Страница 8: ... exhaust with sensor VN NS D24 VN NS D24 VN NJ D24 VN NJ D24 VN Without sensor Model VN S D24 M VN With sensor Model VN S D24 M Vacuum generator manifold mounted alone Individual air supply port type Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfold Common air supply port type Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfol...

Страница 9: ...Silencer without sensor Model VNP D24 M VNP Silencer with sensor Model VNP D24 M Extarnal vacuum controller manifold stand alone Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfold External vacuum controller manifold only Model Designation VN012B32 Replacement Element Package specification 1 pc in a bag Cautions 1 For please select a vacuum port size 2 For please...

Страница 10: ...ey may cause malfunctions In case they are used under the conditions prepare protect measures 17 Do not use the equipment in locations with inflammable or explosive gas fluid or atmosphere Fire or explosion may occur 18 Do not use the equipment in atmosphere of corrosive gas chemicals seawater water and steam These applications may cause trouble to equipment 19 Do not wash or paint products with w...

Страница 11: ...ification should select pneumatic equipment 2 The applicable conditions of the products in this catalogue are diverse Therefore judge the conformity of systems with required analysis or tests by system designers or persons who is in charge of deciding specifications The guarantee of initial performance and safety of the system is on responsibility of the person who decides specifications Hereafter...

Страница 12: ...c electricity may cause system malfunction or trouble 9 Never use joint other than Tube Fitting Spatter or Tube Fitting Brass where they are exposed to spatter Otherwise can cause fire 10 Carry out maintenance and checks of equipment only after turning power off shutting fluid off and making certain that the pressure in the piping has dropped to zero Please conduct maintenance after confirming fol...

Страница 13: ...OM Polyacetal M6 0 75 0 8 1 0N m 0 59 0 74lbf ft M8 0 75 1 0 2 0N m 0 74 1 48lbf ft R1 8 7 9N m 5 16 6 64lbf ft Taper pipe thread R1 4 12 14N m 8 85 10 33lbf ft White n a R3 8 22 24N m 16 23 17 70lbf ft R1 2 28 30N m 20 65 22 13lbf ft Unified thread No 10 32UNF 1 0 1 5N m 0 74 1 11lbf ft n a SUS304 NBR 1 16 28NPT 7 9N m 5 16 6 64lbf ft National Pipe Thread Taper 1 8 27NPT 7 9N m 5 16 6 64lbf ft Am...

Отзывы: