PISCO VN Series Скачать руководство пользователя страница 1

190

0

50

10

40

90

60

20

30

80

70

Weight

ON

OFF

ON

OFF

Time

Pilot valve signal

Vacuum

Atmospheric pressure

Time

Vacuum

level

Vacuum

level

Vacuum Generator VN

Conventional Vacuum Generator

Large dispersion in response time

Small dispersion in response time

Vacuum

Atmospheric pressure

Pilot valve signal

High speed response

Fine control of the pressure dedicated to

vacuum break prevents small workpieces

blow off.

Gauge Union Type Regulator

Small-sized plug-in Type
Vacuum Filter

Vacuum Pad

Workpiece

Vacuum Generator VN
Indivisual air supply port type

Suction solenoid valve

Air supply PV port for vacuum generation

Air supply PS port for vacuum break

Blow-off flow adjusting needle

Blow-off solenoid valve

Vacuum port (V)

Silencer

Ejector

Vacuum Generator 

VN

 & External Vacuum Controller 

VNP

 Series

Complex Vacuum Generator & External Vacuum Controller for High Speed & Stable Response

C

haracteristics

 Perfect for use in an IC chip loader, IC handlers and other semiconductor manufacturing devices.

 Limited space can be utilized.

Small size and lightweight vacuum generator & external vacuum controller.

In particular, the height is lowered for small space use.

Stand alone type

Manifold type

 High speed, yet stable respose is realized. (ON/OFF=Max. 5msec)

Direct operated solenoid valve is used for the main valve.

 Small workpiece is removed gently at vacuum break with blow-off.

Air supply port for blow-off is independent. Therefore, not only conventional flow adjustment but also using external regulator easily make the fine adjustment of blow-off 

air.

Circuit Diagram

 Common supply port type is also available.

Air supply port for vacuum generation and blow-off are common.

2011̲vacuum-4

11.8.4, 3:36 PM

190

Содержание VN Series

Страница 1: ...um Generator VN External Vacuum Controller VNP Series Complex Vacuum Generator External Vacuum Controller for High Speed Stable Response Characteristics Perfect for use in an IC chip loader IC handlers and other semiconductor manufacturing devices Limited space can be utilized Small size and lightweight vacuum generator external vacuum controller In particular the height is lowered for small space...

Страница 2: ...ltage rating 24VDC Allowable voltage range 10 Surge limiting circuit equipped with surge noise filter Power consumption On start up 2 2W On retention 0 6W equipped with power saving circuit Operation indicator Green LED Operating pressure range 0 79 8psi 0 0 55MPa 0 79 8psi 0 0 55MPa 0 29 6in Hg 100 0kPa 0 79 8psi 0 0 55MPa Valve type Normally closed type Response time Max 5msec at vacuum generati...

Страница 3: ...8mm elbow tube fitting N Common to vacuum making air and blow off air When the port codes of 4 6 8 4L 6L and 8L are selected vacuum making air and blow off air are individisually supplied 2 Vacuum port V Port type Straight tube fitting Elbow tube fitting Code 3 4 3L 4L K Size ø3mm ø4mm ø3mm ø4mm For a combination of different sensors 1 1 Give details in the specification order form 1 Vacuum charac...

Страница 4: ...L side only 4 4R 4H ø4mm straight tube fitting 6 6R 6H ø6mm straight tube fitting 8 8R 8H ø8mm straight tube fitting 4L 4LR 4LH ø4mm elbow tube fitting 6L 6LR 6LH ø6mm elbow tube fitting 8L 8LR 8LH ø8mm elbow tube fitting N Common to vacuum making air and blow off air 1 Vacuum port V Port type Straight tube fitting Elbow tube fitting Code 3 4 3L 4L K Size ø3mm ø4mm ø3mm ø4mm For a combination of d...

Страница 5: ...L left side with the vacuum port to one side Vacuum port Air supply port for vacuum generation PV Air supply port for blow off PS St 1 St 2 St 4 Vacuum generator type Vacuum characteristics Vacuum port V Airsupplyportfor vacuumgeneration PV Air supply port for blow off PS Exhaust port EX Voltage Sensor No of manifold VN D24 External vac controller type Vacuum port V Vacuum supply port PV Air suppl...

Страница 6: ...r type Vacuum characteristics Vacuum port V Airsupplyportfor vacuumgeneration PV Air supply port for blow off PS Exhaust port EX Voltage Sensor No of manifold VN D24 External vac controller type Vacuum port V Vacuum supply port PV Air supply port for blow off PS Voltage Sensor No of manifold VNP D24 L side St 1 St 2 Station No St 3 St 4 St 5 St 6 St 7 St 8 R side St 9 St 10 2011 vacuum 4 11 8 4 3 ...

Страница 7: ...may result in lead wires or connector components broken 2 Compressed air contains plenty of drain Water oxidized oil tar and foreign particles etc Since drain may cause performance drop conduct air dehumidification by the after cooler and drier then improve of air quality 3 Never supply lubricated air 4 Rust and inflow of foreign particles in piping cause malfunction and performance drop Therefore...

Страница 8: ... exhaust with sensor VN NS D24 VN NS D24 VN NJ D24 VN NJ D24 VN Without sensor Model VN S D24 M VN With sensor Model VN S D24 M Vacuum generator manifold mounted alone Individual air supply port type Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfold Common air supply port type Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfol...

Страница 9: ...Silencer without sensor Model VNP D24 M VNP Silencer with sensor Model VNP D24 M Extarnal vacuum controller manifold stand alone Model Twofold Threefold fourfold fivefold sixfold sevenfold eightfold ninefold tenfold External vacuum controller manifold only Model Designation VN012B32 Replacement Element Package specification 1 pc in a bag Cautions 1 For please select a vacuum port size 2 For please...

Страница 10: ...ey may cause malfunctions In case they are used under the conditions prepare protect measures 17 Do not use the equipment in locations with inflammable or explosive gas fluid or atmosphere Fire or explosion may occur 18 Do not use the equipment in atmosphere of corrosive gas chemicals seawater water and steam These applications may cause trouble to equipment 19 Do not wash or paint products with w...

Страница 11: ...ification should select pneumatic equipment 2 The applicable conditions of the products in this catalogue are diverse Therefore judge the conformity of systems with required analysis or tests by system designers or persons who is in charge of deciding specifications The guarantee of initial performance and safety of the system is on responsibility of the person who decides specifications Hereafter...

Страница 12: ...c electricity may cause system malfunction or trouble 9 Never use joint other than Tube Fitting Spatter or Tube Fitting Brass where they are exposed to spatter Otherwise can cause fire 10 Carry out maintenance and checks of equipment only after turning power off shutting fluid off and making certain that the pressure in the piping has dropped to zero Please conduct maintenance after confirming fol...

Страница 13: ...OM Polyacetal M6 0 75 0 8 1 0N m 0 59 0 74lbf ft M8 0 75 1 0 2 0N m 0 74 1 48lbf ft R1 8 7 9N m 5 16 6 64lbf ft Taper pipe thread R1 4 12 14N m 8 85 10 33lbf ft White n a R3 8 22 24N m 16 23 17 70lbf ft R1 2 28 30N m 20 65 22 13lbf ft Unified thread No 10 32UNF 1 0 1 5N m 0 74 1 11lbf ft n a SUS304 NBR 1 16 28NPT 7 9N m 5 16 6 64lbf ft National Pipe Thread Taper 1 8 27NPT 7 9N m 5 16 6 64lbf ft Am...