VFL360-10-200M
VFL360-03-200M, VFL360-G3-200M, VFL360-12-200M
VFL360-04-200M, VFL360-G4-200M, VFL360-16-200M
VFL360-06-200M, VFL360-G6-200M
Element
:
200µm
Flow rate
(
ℓ
/min[ANR]
)
Pressure loss
(
MPa
)
10
100
1000
0.01
0.001
0.0001
How to remove the dust in bowl and replace a filter element
①
Turn the bowl to the arrowed direction (
①
-2)
while pushing down the lock clip(
①
-1).
Align the marking on lock clip to the one on body.
②
Pull down the bowl to detach it from the body.
③
Turn the deflector to the arrowed direction to align its OPEN
▽
marking to
△
marking on the bowl.
④
Detach the deflector from the bowl and take out the filter element from the bowl.
⑤
Take out the baffle from the filter element. (Only for replacement of filter element)
⑥
Remove dust from the bowl and replace the filter element.
⑦
Attach the baffle to the new filter element.
⑧
Place the filter element vertically in the bowl and confirm that the O-ring is on the right position. Attach the deflector to the
bowl with its OPEN
▽
marking aligned with
△
marking on the bowl. Then turn the deflector to align its LOCK
▽
marking to
△
marking on the bowl.
⑨
Insert the bowl to the body with the marking on the lock clip aligned with the marking on the body. Turn the bowl until the lock
clip goes up and lock with a click.
①
-1
①
-2
②
Bowl
Lock clip
Marking on lock clip
Marking on body
④
③
OPEN
▽
marking
LOCK
▽
marking
△
marking on bowl
Filter element
Model code
Filtration accuracy
(
㎛
)
VFE360-1M
1
VFE360-5M
5
VFE360-10M
10
VFE360-200M
200
O- ring
Model code
60×2
Deflector
Model code
VFLD360
Bracket
Model code
VFLB360
* With 2pcs of fixing screw
Baffle
Model code
VFLS360
Proper position of O-ring
http://