background image

INSTALLATION

Pisko

®

 SafeLine

Installation on a Pisko roof walkway

Before installa�on, make sure that the roof walkway(s) in use is installed according to class 2. Pisko SafeLine can only be installed 

on roof walkways with at least 3 roof fixing pieces.

Descrip�on

Pisko roof walkway

Hexagon Flange Bolt M8, stainless steel

SafeLine wire holder bracket

Pisko SafeLine stainless steel wire, 8mm

Hex Flange Nut M8, stainless steel

Part

1

2

3

4

5

Posi�on the SafeLine wire holder bracket (2) 

on the roof walkway (1). Maximum distance 

between brackets is 5 meters.

A�ach bracket (2) with M8 flange bolt and 

flange nut. Avoid damaging the paint on the 

roof walkway during the fastening work.

Bend open the top plate of the 

bracket (2) enough for the wire 

to fit in.

Insert wire (5) in the bracket (2).

When inser�ng the wire inside the bracket (2) make sure the wire is completely 

inside the ring shaped elements of the bracket (2). Otherwise the teeth on the 

bracket (2) might not align correctly with the wire.

Bend the top plate towards 

the lower plate.

Lock the plates together with M8 flange bolt 

and flange nut. The �ghtening torque is 

approx. 30 Nm, or un�l the surfaces are 

completely against each other at the point 

of a�achment.

2

1

4

3

5

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Install the remaining wire holder 

brackets accordingly

Содержание Pisko SafeLine

Страница 1: ... bracket 2 with M8 flange bolt and flange nut Avoid damaging the paint on the roof walkway during the fastening work Bend open the top plate of the bracket 2 enough for the wire to fit in Insert wire 5 in the bracket 2 When inser ng the wire inside the bracket 2 make sure the wire is completely inside the ring shaped elements of the bracket 2 Otherwise the teeth on the bracket 2 might not align corre...

Страница 2: ...inals Excess tension should be avoided Extension of the wire is possible by u lizing ready factory assembled terminals Make the extension by twis ng the male terminal completely inside the female terminal The extension twis ng is easier while the wire coming as an extension is s ll as a roll 6 If the loose end of the wire a er the last bracket has not been equipped with any factory mounted termina...

Страница 3: ... wire holder bracket on a walkway from other manufacturer use at least one le side hole and one right side hole on the ver cal part of the bracket Use 8 mm flange nuts and 8 mm flange bolts when a aching the bracket The hole in the walkway can be max M10 Otherwise follow the steps demonstrated previously in this instruc on Example of using the addi onal a achment holes on the SafeLine wire holder br...

Страница 4: ...ents provided in standard EN 361 and that the harness has not been damaged In addi on adjust the harness to the correct measurements before use of the system and if required also adjust the harness during use Use only proper safety ropes intended to be used as a Personal Protec ve Equipment To ensure the reliability and safety of the products the property owner must carry out yearly inspec on and ...

Отзывы: