INSTALLATION
Pisko
®
SafeLine
Installation on a Pisko roof walkway
Before installa�on, make sure that the roof walkway(s) in use is installed according to class 2. Pisko SafeLine can only be installed
on roof walkways with at least 3 roof fixing pieces.
Descrip�on
Pisko roof walkway
Hexagon Flange Bolt M8, stainless steel
SafeLine wire holder bracket
Pisko SafeLine stainless steel wire, 8mm
Hex Flange Nut M8, stainless steel
Part
1
2
3
4
5
Posi�on the SafeLine wire holder bracket (2)
on the roof walkway (1). Maximum distance
between brackets is 5 meters.
A�ach bracket (2) with M8 flange bolt and
flange nut. Avoid damaging the paint on the
roof walkway during the fastening work.
Bend open the top plate of the
bracket (2) enough for the wire
to fit in.
Insert wire (5) in the bracket (2).
When inser�ng the wire inside the bracket (2) make sure the wire is completely
inside the ring shaped elements of the bracket (2). Otherwise the teeth on the
bracket (2) might not align correctly with the wire.
Bend the top plate towards
the lower plate.
Lock the plates together with M8 flange bolt
and flange nut. The �ghtening torque is
approx. 30 Nm, or un�l the surfaces are
completely against each other at the point
of a�achment.
2
1
4
3
5
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
Install the remaining wire holder
brackets accordingly