TROUBLESHOOTING GUIDE
I f pr o bl e ms ar e n o t f o un d b y t h e f ol l owi n g c h eck s , th en y o u s h o ul d c o n tac t
y o u r Au th o ri z e d P a r ts a nd S e r vi c e D e al e r f o r s e r v i c e . T h e y h a v e t h e
n e c e s s a r y p a rts an d t r ai ni ng to r ep ai r yo u r u ni t qu i c k l y an d e ff i c i e nt l y.
DANGER:
D i s c o n nec t a l l p o we r to u ni t b e fo r e s e rvi c i n g.
Call Piper Products directly at 800-544-3057 if you need further assistance.
Symptoms Possible
Cause
Remedies
Pilot light is off and condensing
unit does not run
No electrical supply
Is the unit plugged in?
Check circuit breaker and fuse.
Check switch on control panel is in "on" position.
Pilot light is on but condensing
unit does not run
Thermostat Control
Is the thermostat control set properly?
Unit does not cool to proper
temperature
Ducting
Are there heating or A/C ducts, make-up air ducts or
fans causing cool drafts?
Not pre-cooled
Has the unit been allowed to pre-cool for at least 30
minutes?
Thermostat Control
Is the thermostat control set properly?
Voltage
Call a service technician.
Does not maintain food
temperature
Air flow
Check condenser coils for proper air flow.
Ducting
Are there heating are A/C ducts, make-up air ducts
or fans causing cool drafts?
Not pre-cooled
Has the unit been allowed to pre-cool for at least 30
minutes?
Food Temperature
Were pans of food placed into the unit at or below
0˚F?
Thermostat Control
Is the thermostat control set properly?
Voltage
Call a service technician.