LIMITED WARRANTY
:
pIpER pRoDucTs warrants to the original purchaser parts and labor for a period of
twelve (12) months from the date of purchase. see manufacturer’s complete warranty for details.
It is our policy to build equipment which is design certified by companies that have been accredited at the Federal Level
by the occupational safety and Health Agency (osHA) and ANsI as a National Recognized Testing Laboratory. These
companies include csA International, underwriters Laboratories, and the National sanitation Foundation. However, a
continuing program of product improvement makes it necessary to submit new models to the agencies as they are
developed. consequently, all models may not bear the appropriate labels at all times.
We reserve the right to change specifications and product design without notice. such revisions do not entitle buyer to
corresponding changes, improvements, additions or replacements for previously purchased equipment. Information is not
for design purposes.
D I S P E N S E R S
D I S P E N S E R S
E L I T E 5 0 0
E L I T E 5 0 0
STEAM TABLES
STEAM TABLES
SUPPORT EQUIPMENT
SUPPORT EQUIPMENT
D R O P - I N S
D R O P - I N S
D-3
SPEC
300 s. 84th Avenue
Wausau, WI 54401
phone: 800-544-3057
Fax: 715-842-3125
www.piperonline.net
Hot Food Wells Drop-In
Top-Mounted Drop-In with Locks
Model#
Length
Width
Inside
Length
Inside
Width
Overall
Height
Inside
Height
Bottom
Indent
Top Cut Out L & W
UL Models Cutouts
for Control box
H x W
CCF-A
22-1/2”
14-1/2”
19-13/16”
11-13/16”
8-1/4”
6-3/8”
1/8”
21-9/16” x 13-9/16”
5-1/4” x 5”
CCF-B
22-1/2”
14-1/2”
19-13/16”
11-13/16”
8”
6-3/8”
1/8”
20-5/16” x 12-5/16”
5-1/4” x 5”
ELECtRiCaL SPECiFiCatiONS
Volts
1000 Wattage
1200
Wattage
1600 Wattage
120 V
8.4 Amps
10.0 Amps
13.4 Amps
208/240 V
4.8/4.2 Amps
5.8/5.0 Amps 7.7/6.7 Amps
BiD SPECiFiCatiONS
Piper’s Top-mount Drop-in is constructed of heavy-duty
deep drawn seamless stainless steel 20 gauge thickness.
The unit can be bottom-insulated or fully-insulated and
is designed to be dropped into a metal counter and
secured with the locking mechanism.
All drains are of stainless steel construction, 1/2 NPT
fused welded to the bottom pan with a stainless steel
removable screen.
Heating element is metal sheath tubular calrod
construction, shaped in a double “U” configuration for
even heat transfer to the well pan.
Element is mounted under the well pan and attached to
an enclosed heat deflector which is fully insulated and
shielded for best BTU transfer.
Deflector pan is installed to well pan with quick-removal
threaded retainers.
Units are either RU recognized component construction
with open wires and controller of either infinite or
thermostatic design or UL listed construction including
electrical conduit and control box with face plate. Units
are standard with thermostats.
101