Manul operation can be used temporarily in case you can not find the remote controller or

test running purpose or maintenance necessary.

OPERATING INSTRUCTIONS

Manual operation

NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.

Operating temperature

Manual

control button

AUTO/COOL

Model A

Model B

Manual

control button

For DUCT and CEILING type, CASSETTE

type, CEILING and FLOOR type and FLOOR and

STANDING type, please refer to the previous pages

to operate the Manual button.

NOTE:

Open and lift the front panel up will see the

manual control button(see Model A)

For some models, the manual control button is

located at the bottom of the unit(see Model B).

Close the panel firmly to its original position.

One press of the manual control button will

lead to the forced AUTO operation. If press

the button twice within five seconds, the unit

will operate under forced COOL operation.

1

3

2

NOTE:

The unit must be turned off before

operating the manual control button. If the

unit is operational, continue pressing the

manual control button until the unit is off.

Mode

Temperature

Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures.If air

conditioner is used outside of the above conditions, certain safety protection features

might come into operation and cause the unit to function abnormally.

2. If the air conditioner operates in a room whose relative humidity is less than 80%

the surface of the air conditioner may attract condensation. Please sets the vertical

air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion:

For the unit adopts an Electric Heater, when the outside ambient temperature

is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to

guarantee it running smoothly.

O

O

NOTE:

Cooling operation

Heating operation

Drying operation

17 ~32

62

O

O

O

O

C

C(

F~90 F)

0 ~30

2

O

O

O

O

C

C(3 F~86 F)

-15

50

5

122

For the models with low

temperature cooling system

0

50

O

O

C~

C

(32

122

O

O

F~

F)

-15

24

O

O

C~

C

(5

76

O

O

F~

F)

Manual control button

17 C~32 (62 F~90 )

O

O

O

O

C

F

0 C~50 C

(32 F~122 F)

O

O

O

O

Содержание YN018-2

Страница 1: ...oor Ceiling FB Floor Console Indoor Units Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troublesh...

Страница 2: ...to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only CAUTION SOCIABLE REMARK Sociable remark 2 SAFETY PRECAUTIONS Warning 3 Caution 4 OPERATING INSTRUCTIONS Identification of parts 5 Operating temperature 17 Manual operation 17 Airflow direction control 18 Ho...

Страница 3: ... may cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It contains contaminants and could make you sick It may cause fire and electric shock It may cause electric shock or fire This could damage your health No installation may cause fire and ele...

Страница 4: ...ot operate your air conditioner in a wet room such as a bathroom or laundry room Do not place obstacles around air inlets or inside of air outlet Do not use strong detergent such as wax or thinner Use a soft cloth for cleaning If bracket is damaged there is concern of damage due to falling of unit Children should be supervised to ensure that they do not play with the appliance There is danger of f...

Страница 5: ... Stop valve 13 Fan hood 10 11 12 13 Indoor unit Air outlet Air inlet 1 Panel frame 2 Rear air intake grille 3 Front panel 4 Air Purifying filter Air filter behind 5 Horizontal louver 6 LCD display window 7 Vertical louver 8 Manual control button behind 9 Remote controller holder 8 run ion timer def Display window NOTE The display window on the air conditioner you purchased may look like one of the...

Страница 6: ...IR display optional Displayed when CLEAN AIR feature is activated TURBO operation display Displayed when select TURBO function on cooling operation or on heating operation DIGITAL DISPLAY Displays the current setting temper ature when the air conditioner is in operation FAN SPEED display Displayed the selected fan speed LOW MED and HIGH Ion OPERATING INSTRUCTIONS This display is separated into fiv...

Страница 7: ...ation DEFROST indication lamp or Fan only indication lamp Cooling Heating models only Cooling only type Lights up when the air conditioner starts defrosting automatically in heating operation or fan only mode is selected Temporary button This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted One press of the manual control butt...

Страница 8: ...dication lamp This indicator illuminates when the unit is operational TIMER indication lamp Lights up during Timer operation AlARM indication lamp Flashes when malfunction occurs DEF FAN indication lamp Lights up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models 3 1 ...

Страница 9: ...rate the unit temporarily in case you misplace the remote controller or its batteries are exhausted One press of the manual control button will lead to the forced AUTO operation If press the button twice within five seconds the unit will operate under forced COOL operation The forced COOL operation is used for testing purposes only please do not choose it unless it is necessary Temperature Display...

Страница 10: ...ghts up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models 7 8 9 10 Infrared signal receiver Digital display window MANUAL OPERATION TIMER DEF FAN ALARM MANUAL button This button is used to operate the unit temporarily in case you misplace the remote controller or its...

Страница 11: ... lamp Lights up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models 5 6 7 8 TEMPORARY button This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted One press of the manual control button will lead t...

Страница 12: ...on AlARM indication lamp Flashes when malfunction occurs PRE DEF FAN indication lamp Lights up when the air conditioner starts defrosting automatically in heating operation applicable to cooling heating models only or fan only mode is selected applicable to cooling only models TEMPORARY button This button is used to operate the unit temporarily in case you misplace the remote controller or its bat...

Страница 13: ...ff before operating the manual control button If the unit is operational continue pressing the manual control button until the unit is off Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into operation and cause th...

Страница 14: ...ted to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Range Range Vertical louver Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal vertical louver using the remote controller For some models the vertical louver can only be adjusted manually Perform thi...

Страница 15: ...louver will swing up and down left and right automatically Manual Swing Adjust the louver to achieve better cooling heating effects when cooling heating When cooling Adjust the louver horizontally When heating Adjust the louver downwards vertically Ceiling Floor Type NOTE The heating operation with horizontal air out let will increase the difference of the room temperature Notice Notice the louver...

Страница 16: ...er will automatically increase cooling or decrease heating 1 2 F per hour The set temperature will be steady 2 hours later And the air conditioner will be timer off in 7 hours The fan speed will be automatically controlled This feature can maintain the most comfortable temperature and save more energy for you The fan speed will be automatically controlled under dry operation During the dry operati...

Страница 17: ...the other units can operate under heat mode only OPERATING INSTRUCTIONS Operation mode selection To achieve optimal performance please note the following Adjust the air flow direction correctly so that it is not directed on people Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels Close doors and windows on COOL or HEAT modes or perfo...

Страница 18: ...ntenance Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops with a clicking sound 2 Take hold of ...

Страница 19: ... metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution Air freshening filter Air freshening filter 4 Remove the Silver Ion filter Bio filter Vitamin C filter from its support frame The installation and removing m...

Страница 20: ... air filter 4 Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place 1 Open the air in grill Push the grill switches towards the middle simultaneously as indicated in follow figure sketch Then pull down the air in grill Cautions The control box cables ...

Страница 21: ...r with water or vacuum cleaner then dry it in cool place 4 Re install the air filter in the reverse order of Fig E2 1 Open the front panel Refer to Fig F1 For 48000Btu h models 1 Directly pull out the air filter from air inlet as indicated in Fig E3 2 Clean the air cleaning filter with water or vacuum cleaner then dry it in cool place 3 Re install the air filter in the reverse order of Fig E3 Fig ...

Страница 22: ... The expecial function filter can be renewed by washing it with water once every 6 months We recommend replacing it once every 3 years Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner see Fig F4 The air in side...

Страница 23: ...p slightly to let the position retainer escape away from the flange fixed holes and take off the filter according to the arrow direction shows in the Fig G2 3 Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place 4 The air in side should face up when ...

Страница 24: ...unning when defrosting Cooling and heating models only Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner During this condition air conditioner will stop heating operation and start defrosting automatically The time to defrost may vary from 4 to 10 minutes according to the ou...

Страница 25: ...The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air cond...

Страница 26: ...d Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctly For detailed method please refer to Remote controller instruction section Clean the air filter Close the doors or windows Clear obstructions away first then restart the unit Wait Inappropriate temperature setting Air filter is blocked Doors or Windows are ope...

Страница 27: ...CS464 U2 202000191054 20131011 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Отзывы: