Table 5.1
Table 5.2
Page 8
Specifications
5
Outdoor Unit
Specifications
Number of units that can be used
together
Connected units
1 to 5 units
Compressor stop/start frequency
Stop time
3 min or more
voltage fluctuation
within ±10% of rated voltage
Power source voltage
voltage drop during start
within ±15% of rated voltage
interval phase unbalance
within ± 3% of rated voltage
2 Zone
3 Zone
Max. length for all rooms
40
/
130
60/200
Max. length for one indoor unit
25/80
30/
100
Max. height different between indoor and outdoor unit
15/50
15/50
Max. height different between indoor units
10/33
10/33
4 Zone
5 Zone
80/260
80/260
35/115
35/115
15/50
15/50
10/33
10/33
Unit: m/ft.
10m(33ft)
When installing multiple indoor units to work with a single outdoor unit, ensure that the length of the
refrigerant pipe and the drop height between the indoor and outdoor units meet the requirements
illustrated in the following diagram:
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
15m(50ft)
15m(50ft)
Max.Height difference