XV-EV61
132
1
2
3
4
1
2
3
4
C
D
F
A
B
E
4
When DC is generated at the output because of
a failure in the AMP system, etc.
5
When abnormally high temperature is detected
by the thermistor
R3605
(R3625)
(R3615)
27k
R3606
(R3626)
(R3616)
27k
R3638
10k
Front L ch
(SW, SL)
+5V
C3632
470/6.3
Q3637
Q111
2SC4081
R113
220
IC81
R112
1k
TH111
NCP18WF104J03RB
R111
1k
Q3638
Q3632
Q3633
B
C
E
+
XPROTECT
to
XPROTECT
SP-TERMINAL
Assy
N
R108
27k
VD+5
VD+5
EVOL
Assy
K
Front R ch
(C, SR)
• In Normal mode, both Q3637 and Q3638 are off.
(1) When positive (+) DC voltage is generated at the SP
terminal
When positive (+) DC voltage is generated at the L or R channel,
and VB of Q3637 becomes higher than that at the operation point,
Q3632 (E, C, B) is turned on, and the level of XPROTECT
becomes low.
→
The microcomputer detects the XPROTECT level and shuts
the power to the unit off.
(2) When negative (-) DC voltage was generated at the SP
terminal
Q3638 is turned on, and XPROTECT is activated.
5
-1 IC81 abnormal temperature detection circuit
5
-2 D22 abnormal temperature detection circuit
A
Q131
2SC4081
R133
220
D22
R132
680
1%
TH131
NCP18WF104J03RB
R131
560
1%
to
XPROTECT
VFL+5
A
The voltage at Point
A
becomes the divided voltage of TH111
and R111//R112 (combined resistance of parallel-connected
resistors R111 and R112.) In Normal mode, the resistance at
TH111 is much higher than R111//R112, and Q111 is off. (Note
that the resistance at TH111 becomes lower as the temperature
increases.) If the solder temperature at IC81 increases abnormally,
the temperature at TH111 (thermistor) mounted closest to the land
of IC81 increases accordingly, and the resistance at TH111
decreases.
When the temperature at TH111 reaches 90-110_C (varying
according to conditions,) the voltage at Point (A) becomes high
enough to turn Q111 on, and the level of the XPROTECT line
becomes low. The microcomputer detects the XPROTECT level
and shuts the power to the unit off.
If the solder temperature at D22 becomes abnormally high
because of short-circuiting between AC - and +, or AC - and -, this
protection circuit is activated.
The voltage at Point
A
becomes the divided voltage of TH131
and R131//R132 (combined resistance of parallel-connected
resistors R131 and R132.) In Normal mode, the resistance at
TH131 is much higher than R131//R132, and Q131 is off. (Note
that the resistance at TH131 becomes lower as the temperature
increases.) If the solder temperature at D22 increases abnormally,
the temperature at TH131 (thermistor) mounted closest to the land
of D22 increases accordingly, and the resistance at TH131
decreases.
When the temperature at TH131 reaches 107-125_C (varying
according to conditions,) the voltage at Point (A) becomes high
enough to turn Q131 on, and the level of the XPROTECT line
becomes low. The microcomputer detects the XPROTECT level
and shuts the power to the unit off.
Содержание XV-EV31
Страница 34: ...XV EV61 34 1 2 3 4 1 2 3 4 C D F A B E 3 7 DVDM ASSY 3 3 B 3 3 B 2 3 ...
Страница 50: ...XV EV61 50 1 2 3 4 1 2 3 4 C D F A B E 3 15 MIC ASSY J H P ASSY XWZ3731 O O K CN3008 JA5401 JA5402 ...
Страница 55: ...XV EV61 55 5 6 7 8 5 6 7 8 C D F A B E AUDIO SIGNAL ROUTE FL M The power supply is shown with the marked box ...
Страница 58: ...XV EV61 58 1 2 3 4 1 2 3 4 C D F A B E 3 19 PRIMARY ASSY P J3009 K 1SS133 1SS133 ...