OPERATING INSTRUCTIONS

Airflow direction control

   Adjust the air flow direction properly otherwise it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal/vertical louver using the remote 
   controller. For some models, the vertical louver can
   only be adjusted manually.

  

To set the horizontal/vertical air flow direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow direction. 
   The vertical/horizontal louver changes 6 degree in angle
    for each press, or swing up and down automatically. 
    Please refer to the   REMOTE CONTROLLER OPERATION 
    MANUAL    for details. 
   

   

   

For some models, the vertical louver can only be adjusted
manually. Move the deflector rod  manually to adjust the air 
flow in the direction you prefer.

IMPORTANT

:Do not put your fingers into the panel of 

blower and suction side.

The high-speed fan inside may 

cause danger.

    

Do not operate the air conditioner for long periods with 
the air flow direction set downward in cooling or 
dehumidifying mode. Otherwise, condensation may 
occur on the surface of the horizontal louver causing
 moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it 
was stopped, the horizontal louver might not move for 
approximately 10 seconds.
Open angle of the horizontal louver should not be set 
too small, as COOLING or HEATING performance may 
be  impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise
 the horizontal louver will be out of sync. Please cease 
operating, unplug power for a few seconds,then restart 
the air conditioner.
Do not operate unit with horizontal louver in closed 
position.

CAUTION

,,

,,

OPERATING INSTRUCTIONS

NOTE: This manual does not include Remote Controller Operations, see the 
<<Remote Controller Instruction>> packed with the unit for details. 

Deflector rod

Range

Range

Manual control button

Suspension bars

Manual control button

AUTO/COOL

AUTO/COOL

1

2

Manual operation

Operating temperature

Manual switch

Manual switch

Mode

Temperature
Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures.If air 
    conditioner is used outside of the above conditions, certain safety protection features 
    might come into operation and cause the unit  to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 
    80%)

 , condensed water may drip out of the unit. Please sets the vertical air flow louver to

    its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: 

 For the unit adopts an Electric Heater, when the outside ambient  temperature

O

O

 is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to 
guarantee it running smoothly.

NOTE:

Cooling operation

Heating operation Drying operation

-15      50      5      122 

  For the models with low 

   temperature cooling system

0      50

32      122

-15      30

5        86

0      50

32      122

Open and lift the front panel up to an angle 
until it remains fixed  with a clicking sound. 
For some models, please use suspension
bars to prop up the panel.

One press of the manual control switch will 
lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original 
position.

This switch is used for testing purposes 
only. You had better not choose it.
To restore the remote controller operation, 
use the remote controller directly.

CAUTION:

1

3

2

NOTE:

 The unit must be turned off before

operating the manual control button. If the 
unit is operational, continue pressing the 
manual control button until the unit is off.

O

O

17 C~32 C

O

O

(62 F~90 F)

O

O

0 C~30 C

O

O

(32 F~86 F)

O

O

10 C~32 C

O

O

(50 F~90 F)

Units are equipped with a switch to run emergency operation mode. It can be accessed by 
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.

Содержание WYQ Series

Страница 1: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CS159U BP11M 202000192485 20140314 Before using your air conditioner please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with the sale...

Страница 2: ... in the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the a...

Страница 3: ...all the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open or if the humidity is very high Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of any abnormalities such as smell of burning imm...

Страница 4: ...nction Optional After the AC starts up users can control the vertical louver swing by the remote controller SELF CLEAN function Optional Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation The unit will operate as following sequence FAN ONLYmode at Low fan speed Heating operation with LOW fan speed applicable to cooling heating...

Страница 5: ...Range Range Manual control button Suspension bars Manual control button AUTO COOL AUTO COOL 1 2 Manual operation Operating temperature Manual switch Manual switch Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come int...

Страница 6: ...and the air conditioner may stop running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is O O lower than 10 C 50 F the compressor stops operation and restarts until the room temp...

Страница 7: ...ompressor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached A When heating has just started B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrostin...

Страница 8: ...rawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit completely For the unit w...

Отзывы: