Air Conditioner Service Manual
19
9. Installation manual
9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid
Gas
WYT009GLFI19RL
1/4
3/8
WYT009ALFI19RL
1/4
3/8
WYT012GLFI19RL
1/4
3/8
WYT012ALFI19RL
1/4
3/8
WYT018GLFI19RL
1/4
3/8
WYT024GLFI19RL
1/4
1/2
WYT036GLFI19RL
WYT009GLFI19RL
WYT009ALFI19RL
WYT012GLFI19RL
WYT012ALFI19RL
WYT018GLFI19RL
WYT024GLFI19RL
WYT036GLFI19RL
1/4
5/8
Model
Standard
length:
m
(Inch)
Refrigerant piping
Max. length: m (Inch)
A
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
5.0(19.7)
5.0(19.7)
15(59)
20g/m
(20g/3.94)
15(59)
20g/m(20g/3.94)
5.0(19.7)
15(59)
20g/m(20g/3.94)
5.0(19.7)
15(59)
20g/m(20g/3.94)
5.0(19.7)
15(59)
30g/m(30g/3.94)
5.0(19.7)
15(59)
30g/m(00g/3.94)
5.0(19.7)
15 (59)
30g/m(30g/3.94)
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Wire Size
5
AWG21/0.75 mm2
10
AWG18/1.0 mm2
13
AWG15 /1. 5 mm2
18
AWG14/1.6 mm2
25
AWG12/2.0 mm2
30
AWG10/2.5 mm2
Outdoor unit
Pipe length is 15
m(59Inch) Max.
He
ight
sh
ou
ld be
less tha
n 5m
(19.7Inch)
Indoor unit
Outdoor unit
Pipe length is 15
m(59Inch) Max.
Indoor unit
He
ight
sh
ou
ld be
less tha
n 5m (19.7Inch)