6. EACH SETTING AND ADJUSTMENT
6.1 IDLE CURRENT ADJUSTMENT
1. Idle Current Adjustment
• Adjustment Point and Measurement Points
.... see fig1.
AMP ASSY
[Fig. 1]
SIDE A
Idle current
VR: V1201
FL
TP1201
FL
1 PIN
TEST POINT (–)
TP1201
FL
3 PIN
TEST POINT (+)
TP1201
SBR
3 PIN
TEST POINT (+)
TP1201
SBR
1 PIN
TEST POINT (–)
TP1201
SBL
3 PIN
TEST POINT (+)
TP1201
SBL
1 PIN
TEST POINT (–)
TP1201
FR
3 PIN
TEST POINT (+)
TP1201
FR
1 PIN
TEST POINT (–)
Idle current
VR: V1201
C
Idle current
VR: V1201
SR
Idle current
VR: V1201
FR
Idle current
VR: V1201
SBL
Idle current
VR: V1201
SBR
Idle current
VR: V1201
SL
TP1201
C
3 PIN
TEST POINT (+)
TP1201
C
1 PIN
TEST POINT (–)
TP1201
SR
3 PIN
TEST POINT (+)
TP1201
SR
1 PIN
TEST POINT (–)
TP1201
SL
1 PIN
TEST POINT (–)
TP1201
SL
3 PIN
TEST POINT (+)
Measurement Points
Adjustment
Points
Procedure
V1201
FL
TP1201
FL
3PIN : TEST POINT(+)
TP1201
FL
1PIN : TEST POINT(–)
1
Turn on the power.
2
Perform aging for one minute.
3
Connect a digital voltmeter to the measurement point.
4
Turn the adjustment VR so that the voltage becomes
in 2.0 mV ± 0.2 mV.
(Condition : No signal and no load)
V1201
FL
TP1201
FR
3PIN : TEST POINT(+)
TP1201
FR
1PIN : TEST POINT(–)
V1201
C
TP1201
C
3PIN : TEST POINT(+)
TP1201
C
1PIN : TEST POINT(–)
V1201
SL
TP1201
SL
3PIN : TEST POINT(+)
TP1201
SL
1PIN : TEST POINT(–)
V1201
SR
TP1201
SR
3PIN : TEST POINT(+)
TP1201
SR
1PIN : TEST POINT(–)
V1201
SBL
TP1201
SBL
3PIN : TEST POINT(+)
TP1201
SBL
1PIN : TEST POINT(–)
V1201
SBR
TP1201
SBR
3PIN : TEST POINT(+)
TP1201
SBR
1PIN : TEST POINT(–)