PDR-L77
6.4 ADJUSTMENT 1 (LASER DIODE POWER ADJUSTMENT)
[Procedure]
(1) Check that "CD" is displayed on the FL display. If "CD-R" or "CD-RW" is displayed, press the ERASE button repeatedly until "CD" is
displayed.
(2) Press the RECORD button.
(3) Press the REC MUTE button. The LED for confirmation of LD emission will light in red. The LD is emitting in this status.
(4) Turn VR101 clockwise until the adjustment value to be reached is obtained.
(5) Press the STOP button to shut off the LD.
6.4.1 Playback Power Adjustment
Pickup objective lens
Test Point
Adjustment Point
Adjustment Value
VR101 (PB. PW)
0.60 mW
±
0.05 mW
Fig. 4 Adjustment points
Playback power
Playback
CD-R recording
CD-R overdrive
CD-R record
power
CD-RW record power
CD-RW bias
power
CD-RW recording
Fig.5 Output power of the laser diode
CD-RW erase
power
Note 1 : Attach the remote sensor of the laser power meter to a
point angled away about 10 degrees against the pickup
lens and where the maximum power is detected, so that
there will be no light reflected onto the pickup.
Note 2 : When adjusting with VRs, first turn them completely
counter-clockwise and then adjust clockwise, so that the
value to be reached is not exceeded.
Note 3 : The wave length setting of the laser power meter is
assumed to be 780nm.
CN102
VR101
PB. PW
VR164
RW ERASE
VR163
R REC
VR141
RW BIAS
VR162
R O.D.
VR161
RW REC
1
1 : RF
2 : VC
3 : MPP
4 : TE
5 : VC
6 : FE
6
CD-R CORE ASSY
DANGER – LASER RADIATION WHEN OPEN.
AVOID DIRECT EXPOSURE TO BEAM.
Содержание PDR-L77
Страница 21: ...PDR L77 21 A B C D 5 6 7 8 5 6 7 8 3 5 A CDR SERVO AMP MULTI PLEXER A1 5 A4 5 A3 5 A1 5 1 ...
Страница 43: ...PDR L77 43 A B C D 1 2 3 4 1 2 3 4 Q7006 Q7009 Q7051 PWSB ASSY G ANP7337 B SIDE B G ...
Страница 45: ...PDR L77 45 A B C D 1 2 3 4 1 2 3 4 SIDE B FLDP ASSY 1 2 H FLDP ASSY 2 2 H ANP7337 B H ...
Страница 68: ...68 PDR L77 FL TUBE 7 2 2 DISPLAY AAV7074 FLDP ASSY V7001 Grid Assignment Pin Connection 1 45 90 46 ...
Страница 69: ...69 PDR L77 Anode Connection ...