PDP-R06G
39
5
6
7
8
5
6
7
8
C
D
F
A
B
E
6.5 OUTLINE OF COMMANDS
QS1:
Returning information on the module and the version of the software.
If you want to see version information (ex. QS1,QS6,Factory Menu), Please see 10 seconds after starting.
QS6:
Returning information of the Flash Device.
QMT:
Returning information of MR temperature and FAN speed.
Order
Part
Data Content
Size
Remarks
0
-
Received Command Name on MR
3 byte
'QS1' only
1
MDU
Display Information 1
1 byte
2
Display Information 2
1 byte
3
Display Information 3
1 byte
4
Display Information 4
1 byte
5
Display Information 5
1 byte
6
Boot Version of Module microcomputer.
3 byte
7
Program Version of Module microcomputer.
8 byte
8
Boot Version of ASTRA-MANTA
3 byte
9
Program Version of ASTRA-MANTA
8 byte
10
Sequence Version (43VIDEO)
4 byte
11
Sequence Version (43PC)
4 byte
12
Sequence Version (50VIDEO)
4 byte
13
Sequence Version (50PC)
4 byte
14
MR
, (comma)
1 byte
15
MR Information 1
1 byte
16
MR Information 2
1 byte
17
MR Information 3
1 byte
18
MR Information 4
1 byte
19
Version of IF microcomputer
4 byte
20
Version of Main microcomputer
8 byte
21
Boot Version of Main microcomputer
4 byte
22
Program Version of CARRERA-MANTA
8 byte
23
Boot Version of CARRERA-MANTA
4 byte
24
GUI Version of CARRERA-MANTA
8 byte
25
Enhanced Version of CARRERA-MANTA
8 byte
26
PIC Version of CARRERA-MANTA
8 byte
Order
Data Content
Size
Remarks
0
Received Command Name on MR
3 byte
'QS6' only
1
Version of Text
60 byte
2
User Password
4 byte
Order
Data Content
Size
Remark
1
Received Command Name on MR
3 byte
'QMT' only
2
MR Temperature
3 byte
3
MR FAN Speed
1 byte
0: STOP
1: MIN
2: MAX