7.1.6 HOW TO CLEAR HISTORY DATA
Clearing data on various histories when the OB DIGITAL Assy is replaced
Other than adjustment data for the panel unit, data to be backed up include the accumulated power-on time and a history of defective parts,
which are data updated and stored in memory. Among those data, some are required to be cleared when the OB DIGITAL Assy is replaced
for servicing, as shown below:
Notes:
1: With the PDP-436SXE/RXE and subsequent models, because various compensation functions use pulse-meter data for calculating
compensation values, if related Assys are replaced, data on various histories must be cleared.
2: To clear data using RS-232C commands, after entering Factory mode (by sending FAY or PFY), issue a corresponding command.
Otherwise, the command will not be executed.
Item
Backed-up data
Type of servicing
RS-232C
command
Panel
replacement
Replacement of the
power-supply block
Others
Hour meter
Accumulated display
To be cleared
Not to be cleared
Not to be
cleared
CHM
SD history
Point where an SD
occurred and data on the
hour meter
To be cleared
Not to be cleared
Not to be
cleared
CSD
PD history
Point where a PD
occurred and data on the
hour meter
To be cleared
Not to be cleared
Not to be
cleared
CPD
Pulse meter
Accumulated number of
pulses of the Panel (5
blocks)
To be cleared
(essential)
Not to be cleared
Not to be
cleared
CPM
Accumulated number
of power-ons
Accumulated number of
RELAY_ONs
Not to be
cleared
To be cleared
(essential)
Not to be
cleared
CPC
Содержание PDP-436RXE
Страница 9: ...PDP 436SXE 9 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 25: ...PDP 436SXE 25 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only ...
Страница 27: ...PDP 436SXE 27 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only SXE Only ...
Страница 145: ...PDP 436SXE 145 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT OBE MAIN ASSY IC4804 AV SW ...
Страница 146: ...PDP 436SXE 146 1 2 3 4 1 2 3 4 C D F A B E Block Diagram R2S11001FT OBE MAIN ASSY IC4806 Component SW IC ...