PDP-435PE
50
1
2
3
4
1
2
3
4
C
D
F
A
B
E
[A]
ABL
ABN
ABY
AMN
AMY
[B]
BAL
BAS
BCP
[C]
CHM
CPD
CPM
CSD
[D]
DRF
DRN
[F]
F50
F60
F61
F70
F72
F75
FAJ
FCN
FCY
[G]
GAJ
GNP
GPD
GPW
GS1
GS2
GSD
[M]
M00
M01
M02
M03
M04
M10
M11
M12
M13
M14
M15
M20
M21
M22
M23
M24
M25
M26
M27
M28
M29
M2E
M2F
M30
M31
M51
M52
M53
M54
M55
M56
M57
000
98
121
255
158
135
ABL ADJUSTMENT
PEAK ABL NO
PEAK ABL YES
AUDIO MUTE NO
AUDIO MUTE YES
BALANCE ADJUSTMENT
BASS ADJUSTMENT
BACKUP COPY
CLEAR HOUR METER
CLEAR POWER DOWN
CLEAR PLUSE METER
CLEAR SHUT DOWN
DRIVE OFF
DRIVE ON
FREQENCY VIDEO 50Hz
FREQENCY VIDEO 60Hz
FREQENCY PC 60Hz
FREQENCY PC 70Hz
FREQENCY VIDEO 72Hz
FREQENCY 75Hz
FINISH ADJUSTMENT
FOCUS NO
FOCUS YES
GET ADJUSTMENT
GET NUMBER PANEL
GET POWER-DOWN
GET PANEL WHITE BALANCE
GET STATUS 1
GET STATUS 2
GET SHUT DOWN
MASK MODE 0
MASK MODE 1
MASK MODE 2
MASK MODE 3
MASK MODE 4
MASK MODE 10
MASK MODE 11
MASK MODE 12
MASK MODE 13
MASK MODE 14
MASK MODE 15
MASK MODE 20
MASK MODE 21
MASK MODE 22
MASK MODE 23
MASK MODE 24
MASK MODE 25
MASK MODE 26
MASK MODE 27
MASK MODE 28
MASK MODE 29
MASK MODE 2E
MASK MODE 2F
MASK MODE 30
MASK MODE 31
MASK MODE 51
MASK MODE 52
MASK MODE 53
MASK MODE 54
MASK MODE 55
MASK MODE 56
MASK MODE 57
• RS-232C Commands for the module microcomputer
Command Name
Function
Validity of direct numeric input
Validity
Lower limit Upper limit
?
?
?
Adjusting the upper limit of the power
Peak ABL function OFF
Peak ABL function ON
Turning off the audio muting
Turning on the audio muting
Adjusting the audio balance
Adjusting the audio bass
Copying the backup data in the EEPROM
Driving off
Driving on
Setting the frequency in Mask mode to 50 Hz (VIDEO)
Setting the frequency in Mask mode to 60 Hz (VIDEO)
Setting the frequency in Mask mode to 60 Hz (PC)
Setting the frequency in Mask mode to 70 Hz (PC)
Setting the frequency in Mask mode to 72 Hz (VIDEO)
Setting the frequency in Mask mode to 75 Hz (VIDEO)
Turning the FOCUS function off
Turning the FOCUS function on
Obtaining various adjustment values
Obtaining the serial no. of the panel
Obtaining the power-down-point log
Obtaining the panel white-balance adjustment values
Obtaining information on the unit, such as the software version
Obtaining information on the status of the unit, such as the temperature
Obtaining information on shutdown
Turning the Mask function off
White raster (change in luminance level)
White raster--zigzag, exact reverse--scan--gray--white raster
HL--zigzag, exact reverse--scan--gray--white raster
White raster--zigzag, exact reverse--scan--gray--white raster
H ramp (slant 1)
H ramp (slant 4)
H ramp (slant 1 shifting)
H ramp (slant 4 shifting)
V ramp (slant 1)
Slanting ramp
Window (for WB adjustment, Hi = 870, Lo = 102)
Window (for WB adjustment, Hi = 1023, Lo = 102)
Window (for measuring the peak luminance during WB adjustment, Hi = 1023)
Window (for measuring the peak luminance, Hi = 1023, 4%)
Window (for measuring the peak luminance, Hi = 1023, 1.25%)
Window (vertical line with 1/7-width for measuring the stress)
Window (magenta, green, and stripe for check)
Window (green,magenta, and stripe for check)
Window (black & white [1 x 8], checker, for EMG check)
Window (for WB adjustment, magenta = 512, yellow = 512)
Wiper for erasing afterimage
Mask for warning of cable disconnection
ColorBar
Slanted lines (for checking cable disconnection)
Raster-white
Raster-red
Raster-green
Raster-blue
Raster-black
Raster-cyan 1023
Raster-magenta 1023
Determining the flag of the DIGITAL VIDEO Assy adjustment in "adjustment
is completed"
Clearing power-down information
Clearing data of the pulse meter
Clearing data of the hour meter
Clearing shut down information