M-IS22
21
7.1 SINGLE OPERATION METHOD
7. GENERAL INFORMATION
Single operation method and inputlevel.
The procedure and the input level of a single operation are shown below.
1. R85 are shorted by 1k
Ω
.
2. A point of the figure below in four places is connected.
GND is not common because it is independent with chassis GND (GND of the amplifier), B1GND, B2GND, and B3GND.
The potential of B1GND, B2GND, and B3GND is done by connecting A point in four places as well as chassis GND.
2. The power supply of the product is turned on.
3. The terminal CONT (2 pin of CN3332) are controlled respectively by the following voltages.
CONT
12V
5V
0V
RY
ON
ON
OFF
MUTE
OFF
ON
ON
4. The signal of 10mV is input from input terminal (JA3333), and the output is confirmed with speaker terminal (CN3331).
Note : If the music signal is input directly to input terminal (JA3333) with CD PLAYER etc. , the output becomes a large volume because
there are 40dB GAIN of the amplifier.
Caution when disassemble.
Even if the power supply code is pulled out from the outlet, neither C11 nor C12 of AF ASSY are discharged.
Please discharge C11 and C12 of AF ASSY by the resistor of 100
Ω
or more before removing AF ASSY or POWER SUPPLY ASSY.
There is a possibility to destroy the transistor, and Please discharge by the resistor of 100
Ω
or more.
MAIN
ASSY
A
INPUT SIGNAL
10mV
OUTPUT SIGNAL
R85 – 1k
Ω
CONTROLL
0V, 5V or 12V
CONNECT
A POINT (GND)
(FOUR PLACES)
SIDE B
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299