PDP-LX5080D
78
1
2
3
4
1
2
3
4
C
D
F
A
B
E
5.6.3 PROCESSING IN ABNORMALITY
Specifications for port monitoring
Operation specifications of the main CPU
Conditions for resetting the circuits
Port Name
SD/PD Indication
Active
A_NG_B
AUDIO
Shutdown occurs when the signal is "L."
30 mS
∗
3 times
OTW
AUDIO
Shutdown occurs when the signal is "L."
130 mS
∗
3 times
Monitoring conditions
RST4 = "H" (always)
(Monitoring starts 2 sec
after the above conditions
are established.)
Operation
The main CPU operations described below will be
performed when either "A_NG_B = L" or "OTW = L" is
detected (established) under the monitoring conditions.
Port Name
SD/PD Indication
Active
ANT_POW_DET
DTB antenna
short-circuited
Flashing of the LED starts
when the signal is L (100 mS,
3 times)
Monitoring conditions
RST4 = H and
ANT_POW_B = L
Operation
If "ANT_POW_DET = L" is detected (established) under
the monitoring conditions, an SD log is created, and the
LED flashes for 60 sec. A shutdown process is not
performed in the power system.
Protection of the Power Amplifier
A_NG_B
A_NG_B
MAIN_UCOM
PULL_D
OTW
OTW
MAIN Assy
TANSHI Assy
(1) When a shutdown decision is made by the main CPU
• After a warning indication is displayed for 5 sec, a shutdown is generated (the blue LED flashes 5 times).
• A warning indication is displayed for all input-signal types.
• Example of a warning indication: "The speaker terminals are short-circuited. After reconnection, turn the unit on again."
(For 50-inch models) (For 42-inch models, an indication declaring a forced power-off is displayed.)
(2) Display conditions
When the panel is on: A warning indication is displayed immediately.
When the panel is off: A warning indication is not displayed immediately but is displayed when the panel is turned on.
Note:
A warning indication is displayed each time the panel is turned on if the conditions for a shutdown persist.
The circuits will be reset upon Standby ON/OFF.
IF_UCOM
DIGITAL
POWER
AMP IC
Circuit configuration
PULL_D
DTB Antenna power supply
Circuit configuration
Specifications for port monitoring
Inverter
Latch
ON/OFF
Overcurrent
Detection
ANT_POW_B
H: OFF
L: ON
48
47
Monitoring
H: ON
L: OFF
ANT
IF_UCOM
ANT_POW_DET
MAIN Assy
MAIN_UCOM
V+3.3V_STB
V+5.1V_STB
Hold "L" at
the short-circuit.
Содержание KURO PDP-LX508D
Страница 19: ...PDP LX5080D 19 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 20: ...PDP LX5080D 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...PDP LX5080D 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Страница 23: ...PDP LX5080D 23 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 159: ...PDP LX5080D 159 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 170: ...PDP LX5080D 170 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...