KEX-M8547ZT/EW
40
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Connection:
Setting of the pulse generator. (setting of superimposed pulse)
Adjustment:
1. Setting of SSG
Receiving frequency
: 999 kHz
Percentage modulation : 30%
Modulation frequency : 400 Hz
Antenna input
: 74 dB
µ
V (EMF)
2. Tune a RADIO to the "999kHz" with 1 condition.
3. .Mix signal with the above-mentioned pulse and
SSG moduration OFF .
4. Variable resistance adjust noise level to a
minimum.
Adjustment point : VR561
Pulse generator
(equivalent to HP8011A)
SSG
2-signal pad
AM dummy
KEX-M8406ZT
KEX-M9406ZT
Output
Noise meter
Pulse width :50
µ
sec
Pulse intervals :5msec
Pulse voltage :4Vp-p
4Vp-p(EMF)
50us
5ms
AM NOISE CANCELER ADJUSTMENT
KEX-M8547ZT/EW
KEX-M8647ZT/EW