Page 29
Air Evacuation
7
Preparations and Precautions
Air and foreign matter in the refrigerant circuit
can cause abnormal rises in pressure, which
can damage the air conditioner, reduce its
efficiency and cause injury. Use a vacuum pump
and manifold gauge to evacuate the line sets
circuit, removing any non-condensable gas and
moisture from the system.
Evacuation should be performed upon initial
installation and when unit is relocated.
BEFORE PERFORMING EVACUATION
Check to make sure that both high-
pressure and low-pressure pipes between
the indoor and outdoor units are
connected properly in accordance with the
Refrigerant Piping Connection section of
this manual.
Check to make sure all wiring is connected
properly.
Evacuation Instructions
Before using the manifold gauge and vacuum
pump, read their operation manuals to familiarize
yourself with how to use them properly.
Manifold Gauge
Low pressure gauge
-76cmHg
Low pressure valve
High pressure
valve
Blue (low)hose
Yellow (middle) hose
Vacuum
pump
High pressure gauge
Low pressure valve
1.
Connect the blue (low) hose of the manifold
gauge to service port on the outdoor unit’s
low pressure valve (use an adapter if needed)
2.
Connect yellow (middle) hose from the
manifold gauge to the vacuum pump.
MC
MC
Fig. 6.1
Air Evacuation