95
FH-2816ZF,2716ZF
(2) Relations of keys between TEST and NEW TEST Modes
Keys
Test Mode
New Test Mode
Regulator OFF
Regulator ON
PLAY in progress
Error Occurred, Protection Activated
5
Regulator ON
Regulator OFF
¾
Time of occurrence / cause of error select
TRACK UP
¾
FWD-Kick
TRACK UP / FF
¾
TRACK
¾
REV-Kick
TRACK
¾
DOWN
DOWN /REV
3
¾
Tracking close
SCAN
¾
4
¾
Tracking open
MODE
¾
1
¾
Focus close
¾
¾
SCAN
To New Test
Focus Mode
AUTO/MANU
¾
Mode
Select
Operations,such as EJECT, CD ON/OFF, etc. are performed normally
(3) Error Cause (Error Number) Code
Error Code
Classification
Mode
Description
Cause
Detail
40
ELECTRIC
PLAY
FOK=L
Put out of focus
Scratch,
41
ELECTRIC
PLAY
LOCK=L 150ms
Spindle unlock
Stain,
42
ELECTRIC
PLAY
Subcode
Failed to read subcode
Vibration,
unacceptable 500ms
Servo defect,
43
ELECTRIC
PLAY
Sound skipped
Last address memory
etc...
operated
(4) Indicating an Operation Status During Setup
Status No.
Description
Protection operation
01
Carriage home mode started
None
02
Carriage moving inwards
10-second time out, Home switch failed
03
Carriage moving outwards
10-second time out, Home switch failed
05
Carriage moving outwards
None
11
Setup started
None
12
Spindle turn/Focus search started
None
13
Waiting for focus closure (XSI=L)
Failure to close focus
Waiting for focus closure (FOK=H)
Failure to close focus
Focus closed, Tracking open
Focus disrupted
Focus disrupted
Disrupted focus
Waiting for MIRR, LOCK or subcode read
Focus disrupted, MIRR NG, Failure to lock,
Carriage closed, SPINDLE=ADAPTIVE
failed to read subcode
·
Operation (PLAY, SEARCH, etc.) in progress perfectly
identical with that in the normal mode.
·
Protection/Error upon occurrence
(a) Error number indicated
Select the display with the
(b) Track number and
5 key.
absolute time indicated
TNo.
11
Min
11
Sec
11
Er xx
TNo.
10
Min
40
Sec
05
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299