6. SERVICE MODE
6.1 TEST MODE
Key operation
FL display
Display number of times
DC is detected.
Display number of times
OVERLOAD is detected.
Display number of times
COMBINATION is detected.
(Detects DC and OVERLOAD
simultaneously)
Display number of times
Power abnormality is
detected.
Display number of times
AMP overheat is
detected.
[
↓
]
[
↑
]
[
↓
]
[
↑
]
[
↓
]
[
↑
]
[
↓
]
[
↑
]
[
↓
]
[
↑
]
Display number of times
Digital Power abnormality is
detected.
Resetting the number of
times error is detected.
[
↓
]
[
↑
]
[
↓
]
[
↑
]
O L
:
D C
:
:
:
C O M
X P R T
:
S T M P
R E S E T
R E S E T
R E S E T
:
D E R R
The numbers of detections for various protection processes are displayed.
[
↓
] : TUNE key
[
↑
] : TUNE key
[
←
] : PRESET key
[
→
] : PRESET key
During Standby mode, simultaneously press and hold “MULTI-ZONE ON/OFF” and “ENTER” keys for 5 seconds to enter
this mode.Turn off the power to this unit by setting the main volume level to “---dB” and Multi-zone to “OFF”.
R E S E T
H O L D
C L E A R ?
Resetting the number of times error is detected
Key operation
FL display
↓
Continued
[ENTER]
[
←
][
→
]
[1] Detected protection history
[Purpose]
[How to enter]
Turning off the power or pressing the RETURN key returns to the normal mode.
[How to exit]
[Basic operations]
Front Panel Key
Содержание Elite VSX-70
Страница 11: ...11 VSX 1128 K 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 34: ...34 VSX 1128 K 1 2 3 4 A B C D E F 1 2 3 4 2 TEMP Protection Circuit CPU ASSY J AMP7 ASSY K AMP7 ASSY K ...
Страница 51: ...51 VSX 1128 K 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 75: ...75 VSX 1128 K 5 6 7 8 5 6 7 8 A B C D E F ...
Страница 107: ...107 VSX 1128 K 5 6 7 8 5 6 7 8 A B C D E F A SIDE B CP3 CP1 CN3 CN2 CN5 CN1 ...
Страница 119: ...119 VSX 1128 K 5 6 7 8 5 6 7 8 A B C D E F C2916 I SIDE B SIDE B I AUDIO ASSY CP17 CP18 CP12 CP13 CP15 CN2103 ...
Страница 122: ...122 VSX 1128 K 1 2 3 4 A B C D E F 1 2 3 4 J SIDE B J CPU ASSY CN310 CN308 CN309 CN305 CN304 CN306 CN301 Q31 Q31 ...