2.2. FUNC.CHECK
(
Function Check
)
mode
●
Operation item
No.
Display
Content
RS232C
1
FAN
Ù
Forces the setting of FAN speed.
FCN
2
AFT
Ù
Controls AFT action by turning ON/OFF.
AFT
1. FAN
Figure. FAN
Forces the setting of FAN speed (MAX: High speed/MIN: Low speed/STOP: Stops FAN).
NORMAL is for normal operation (i.e. the rotational speed changes according to temperature change).
During Sevice Factory mode, the temperature sensor will operate accordingly to the displayed data.
After exiting the Service Factory mode, the compulsive setting is cancelled, and the FAN wil return to
normal operation mode.
Command
Detail
FCN+S00 NORMAL
FCN+S01 MAX
FCN+S02 MIN
FCN+S03 STOP
If rotational speed was compulsorily changed via 232c command, make sure to return the speed to
normal operation mode when finished.
2. AFT
Exclusively used for production line.
AFT action is stopped, and assign whether to track down or not during channel tuning.