197
PRO-610HD, PRO-510HD, SD-582HD5, SD-532HD5
If POWER SUPPLY ASSY
Brightness Adjustment (
∗
2)
Focus Adjustment (VR1: FOCUS VR) (
∗
2)
Screen Size Adjustment (
∗
2)
Convergence Adjustment (
∗
2)
White Balance Adjustment (
∗
2)
1
3
5
6
7
No adjustment is required
is repaired or replaced
If AV I/O ASSY
No adjustment is required
is repaired or replaced
If OTHER ASSY
No adjustment is required
is repaired or replaced
If DEFLECTION SERVICE ASSY
is repaired or replaced
Brightness Adjustment (
∗
1)
White Balance Adjustment (Composite STD :
∗
1, Others :
∗
2)
1
7
If R, G or B CRT DRIVE ASSY
is repaired or replaced
White Balance Adjustment (
∗
2)
7
If SIGNAL ASSY
is repaired or replaced
Focus Adjustment (
∗
2)
Test-cross Position Check (
∗
2)
Screen Size Adjustment (
∗
2)
Convergence Adjustment (
∗
2)
3
4
5
6
If DIGITAL CONV. ASSY
is repaired or replaced
Brightness Adjustment (
∗
1)
Deflection Yoke Adjustment (
∗
1)
Focus Adjustment (Lens :
∗
2, VR1 Focus VR :
∗
1)
Convergence Adjustment (
∗
2)
White Balance Adjustment (Composite STD :
∗
1, Others :
∗
2)
1
2
3
6
7
If CRT ASSY (R, G or B)
is repaired or replaced
Brightness Adjustment (
∗
2)
White Balance Adjustment (Composite STD :
∗
1, Others :
∗
2)
Panel Adjustment (
∗
1)
Panel Adjustment for DTV (
∗
1)
1
7
8
9
If VIDEO ASSY
is repaired or replaced
Screen Size Adjustment (
∗
2)
Convergence Adjustment (
∗
2)
5
6
If CONV. AMP ASSY
is repaired or replaced
Test-cross Position Check (
∗
2)
White Balance Adjustment (
∗
2)
4
7
If SUB VIDEO ASSY
is repaired or replaced
Focus Adjustment (Lens :
∗
1, VR1 Focus VR :
∗
2)
Convergence Adjustment (
∗
2)
3
6
If LENS ASSY (R, G or B)
is repaired or replaced
Convergence Adjustment (
∗
2)
6
If MIRROR and SCREEN
is repaired or replaced
Note :
*1: Readjustment necessary
*2: Turn on the power and confirm the screen. When adjustment deviates, it is readjusted if necessory.
• When the EEPROMs are replaced, check the status of the unit.
• If any IC of the EEPROM is damaged, readjustment of all the items is necessary.
• The necessary adjustment items differ, depending on the assembly or optical part replaced. Check and readjust the adjustment items
corresponding to the replaced assembly or part, following adjustment procedures 1 to 9.
Example: When the DIGITAL CONV. Assy is replaced, perform the following:
3. Focus check/adjustment
→
4. Test-cross position check/adjustment
→
5. Screen size check/adjustment
→
6. Convergence check/adjustment
Assembly Adjustment Location Guide
Содержание Elite PRO 510HD
Страница 2: ...194 PRO 610HD PRO 510HD SD 582HD5 SD 532HD5 ...
Страница 26: ...218 PRO 610HD PRO 510HD SD 582HD5 SD 532HD5 ...
Страница 73: ...PRO 610HD PRO 510HD SD 582HD5 SD 532HD5 265 ...