PD-D6-J
69
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Display Only POWER-ON sequences
Display-only POWER-OFF sequences
Set time for the current step
Elapsed time
Details on control
0 msec
Display only POWER ON start, Various initial settings
1
All keys are masked.
The normal operation keys are masked.
POWER MUTE ON
SYSTEM POWER1 ON (Pin 91: H)
+ 60 msec
60 msec
Various initial settings
2
+ 240 msec
300 msec
Various initial settings
3
Switched 5 V ON completed (power supply is stabilized)
Masking of the normal operation keys is canceled.
SYSTEM POWER2 ON (Pin 92: H)
+ 60 msec
360 msec
Various initial settings
4
Power-on of the LCD driver starts.
+ 330 msec
690 msec
Display Only POWER ON completed
Set time for the current step
Elapsed time
Details on control
0 msec
Display-only POWER OFF start, Various settings
1
• The mask flags for all the keys are set.
• The mask flags for the normal operation keys are set.
• Muting the power system (SYSTEM MUTE REQUEST)
• Power-off of the LCD driver starts.
+ 4120 msec
4120 msec
Various settings
2
+ 120 msec
4240 msec
Various settings
3
+ 760 msec
5000 msec
Various settings
4
• The mask flags for all keys are set.
• Muting of the power system is canceled.
• Other than in an emergency power-off, the unit awaits for a while.
• SYSTEM POWER2 OFF (Pin 92: H)
+ 240 msec
5240 msec
Display-only POWER OFF completed
• SYSTEM POWER1 OFF (Pin 91: H)