5
1
2
3
4
1
2
3
4
C
D
F
A
B
E
DVR-720H-S
2) After 1), the following screen is displayed on TV monitor.
Press " 043 " by using the remote control unit for service.
6) Escape the Service Mode. Press [ESC].
7) Download the latest firmware.
At last, the download is necessary to update the firmware of each ASSY.
Refer to "7.1.3 DOWNLOAD METHOD" of RRV2963 on page 77.
Notes :
1) After the setting complete, you can NOT CLEAR the setting data.
Make sure the pressing number.
2) " NG " is appeared on TV when unsuitable number is pressed.
In such a case, please unplug the power cable and plug it again. Then restart the model setting.
The setting complete when OSD is disappeared.
3) Unplug the power cable.
4) Reset the recorder to all its factory settings.
1. Make sure that the recorder is on.
2. Press and hold [STOP] and press [STANDBY/ON] key on the front panel.
The recorder turns off with all settings reset.
5) Enter the Service Mode and then confirm the Model Name " DVR-720H/RF ".
1. Make sure that the recorder is on.
2. Press [ESC] then [DISP] keys by using the remote control unit for Service.
[ Recorder 's Model Setting]
Input the number by using the remote for Service.
> --
Input No. Model
[ 42
:
DVR-520H
]
[ 44
:
DVR-720H
]
[ Recorder 's Type Setting]
Input the number by using the remote for Service.
> --- (Type -- , Region No. -)
Input No. Type
[ 02
:
RD/RD
<South Ameraica> ]
[ 03
:
RD/RA
<PX>
]
[ 04
:
RF
<Taiwan>
]
DVR-720H/RF
VERSION
: 4.
∗ ∗
SYSCON
: RELEASE_131
Rev :1.5036
$
TUFLCON
: 4.04
MASK
OK
DRIVE
: DVD-RW DVR-107X
OK
1.13W
OK
CKT0000353WL
OK
HDD
: ST380012ACE
80
DEVICE
: PRISM-PLUS
REGION
: 3
C
:
∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗
FLASH
: 64M
• The Setup is Necessary When :
a) When the MAIN Assy is replaced
b) When the JCKB Assy is replaced
c) When the MAIN Assy and JCKB Assy are replaced Note : Make sure of setting the correct number.
• How to Setup the Model
1) After power on, the following screen is displayed on TV monitor.
Press " 44 " by using the remote control unit for service(GGF1381).
2. MODEL SETTING