4) Read/Write
Indicator
Disc / Status
Indicator Activity
During reading
steady green
During writing
steady orange
When an error occurs
blinking orange
* abnormal rise of
internal temperature
blinks 1 time, pauses then repeats
* lens or disc is dirty
blinks 2 times, pauses then repeats
* other error
blinks 3 times, pauses then repeats
5) Ventilation Holes
– do not block
6) Eject button
press to open and close the tray
7) Forced Ejection hole
if the eject button fails to function, insert a stiff rod into the hole and push gently and
steadily until the disc ejects.
WARNING: Before forcing an ejection, verify that the computer power is OFF and
that the disc has stopped spinning in the drive. The approximate time for a disc to
stop spinning once the power is OFF is 60 seconds.
4.2
Back View and Ports
DVR-A04/104 Back View
8) Audio Output
connector for analog audio output, uses a Modex 70553 connector
Select the appropriate cable from the following chart:
Pin
Name
Function
1
L
Left channel audio output
2
G
Ground
3
G
Ground
4
R
Right channel audio output